100%無料NetApp NCSE NS0-593問題集PDFお試しサンプル認定ガイドカバー率
PDF試験材料2023年最新の実際に出るNS0-593問題集
NS0-593試験の準備をするために、候補者はNetAppトレーニングコースに参加し、公式のNetAppドキュメントをレビューし、ONTAPシステムで実践的な経験を積むことができます。この試験は60の複数選択の質問で構成されており、候補者はそれを完了するのに1.5時間を持っています。 NetApp認定サポートエンジニアONTAPスペシャリスト認定を獲得するには、70%の合格スコアが必要です。
質問 # 10
Recently, a CIFS SVM was deployed and is working. The customer wants to use the Dynamic DNS(DDNS)
capability available in NetApp ONTAP to easily advertise both data UFs to their clients. Currently. DNS is
only responding with one data LIF. DDNS is enabled on the domain controllers.
Referring to the exhibit, which two actions should be performed to enable DDNS updates to work? (Choose
two.)
- A. Enable the -use-secure parameter for the SVM DDNS services.
- B. Enable the -is-enabledparameter for the SVM DDNS services
- C. Remove the NFS protocol from the cifs_01 data LIF.
- D. Disable the -vserver-fqdn parameter for the SVM DDNS services.
正解:B、D
質問 # 11
You are optimizing your Cloud Volumes ONTAP. For interoperability and consolidation purposes, you need
to know the storagelimits.
In this scenario, which source should be reviewed?
- A. Cloud Central
- B. Hardware Universe
- C. Interoperability Matrix Tool (IMT)
- D. NetApp Cloud Volumes ONTAP Release Notes
正解:D
質問 # 12 
Referring to the exhibit, what do you need to do to return the MetroCluster to a normal state?
- A. Enter the storage failover giveback command on Site A.
- B. Enter the metroclustor switchback command on Site B.
- C. Enter the metrocluster switchback command on Site A.
- D. Enter the storage failover giveback command on Site B.
正解:C
質問 # 13
After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is
accessed indirectly. The system node run -node -command netstat command shows retransmits and packet
drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster
interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP
9.8 software.
In this scenario, what is causing this problem?
- A. AFF A300 and AFF A700 node mixing Isnot supported in ONTAP 9.8 software.
- B. The AFF A300 Is using an adapter card for the cluster Interconnect, but only onboard ports are supported.
- C. The 10 Gbps to 10 Gbps cluster Interconnect is creating a speed mismatch.
- D. There is an NXOS firmware mismatch, verify in the Interoperability Matrix (1MTJ for a supportedversion.
正解:C
質問 # 14
Your customer complains that u host will constantly report losing a connection to the iSCSl target and then
report that the session was reestablished.
As shown in the exhibit, what is a cause of this flapping?
- A. A host with an IP address of 172.20.10.80 and a secondIP address of 10.10.20.60 is accessing different LUNs.
- B. A host with an IP address of 172.20.10.80 and a secondhost with an IP address of 10.10.20.60 are in
different initiator groups. - C. A host with an IP address of 172.20.10.80 and a second host with an IP address of 10.10.20.60 are
accessing the same LUN. - D. A host with an IP address of 172.20.10.80 and a second host with an IP address of 10.10.20.60 have the
same IQN.
正解:C
質問 # 15
Your customer Informs you about SnapMlrror problems after upgrading NetApp ONTAP software to a newer
version. After investigating the event logs and the SnapMirror history, you see information about delayed
updates of the SnapMirror relationships.
How would your customer prevent such problems in the future?
- A. Quiesce the SnapMirror relationships before upgrading the ONTAP software.
- B. Modify the schedules of the SnapMirror relationships after upgrading the ONTAP software.
- C. Verify that the cabling of the hardware port that Is responsible for SnapMirror transfers Is correct.
- D. Delete the SnapMirror relationships and create them new after upgrading the ONTAP software.
正解:C
質問 # 16
You have a 2-node NetApp FAS2750 switchless cluster with twenty-four 1.8 TB disks that is experiencing
performance issues. Upon investigation, you discover severaltype B consistency points.
Referring to the exhibit, which corrective action would address these consistency points?
- A. Replace the twenty-four 1.8 TB disks with twelve 4 TB disks.
- B. Convert the 2-node switchless cluster to a 2-node switched cluster.
- C. Create additional data LIFs.
- D. Add an additional shelf oftwenty-four 1.8 TB disks.
正解:D
質問 # 17
A customer reports that some of their client computers are unable to access a FlexGroup over CIFS. This
problem involves only their older Windows XP clients and some printers and scanners.
In this scenario, which statement Is correct?
- A. These systems use Offloaded Data Transfer, which is an unsupported feature in FlexGroup.
- B. These systems use the SMQI protocol which Is an unsupported feature in FlexGroup
- C. FlexGroup requires CIFS shares to use the Continuously Available Feature, which these clients do not
support. - D. FlexGroup requires CIFS shares to be located in qtrees, which these clients do not support.
正解:C
質問 # 18
An administrator receives the following error message:
What are two causes for this error? (Choose two.)
- A. An SSD disk is performing garbage collection to create a dense data layout.
- B. A disk is falling.
- C. There Is excessive SSD load causing the wear leveling to become unbalanced.
- D. There is excessive SATA HDD load.
正解:C、D
質問 # 19
Which two automation methods does NetApp ONTAP Select support? (Choose two.)
- A. PHP
- B. REST
- C. Anslble
- D. Docker
正解:B、C
質問 # 20
You created a new NetApp ONTAP FlexGroup volume spanning six nodes and 12 aggregates with a total size
of 4 TB. You added millions of files to the FlexGroup volume with a flat directory structure totaling 2 TB, and
you receive anout of apace error message on your host.
What would cause this error?
- A. The inode limit is exceeded in the ONTAP software.
- B. The maxdirsize Is exceeded in the ONTAP software.
- C. All constituent volumes are full.
- D. The maximum number of volume constituents has been reached in the ONTAP software.
正解:A
質問 # 21
A storage administrator reports that a monitoring toot is reporting that the storage controller reads between
90% to 93% CPU use. You run the sysstat -m command against thenode in question.
Referring to the exhibit, which statement is correct?
- A. The CPU Is not a first-order monitoring metric for ONTAP.
- B. High network exempt use could be a problem.
- C. The customer should be advised to exclude certain workflows to reduce use.
- D. You should immediately investigate further bygathering perfstat data and opening a support case.
正解:D
質問 # 22
You have a new VMware vSphere cluster with ESXI 7.0U2 hosts. The hosts are connected to a 4-node AFF
A400 NetApp ONTAP9.8 cluster with FC LUNs. You have a requirement to identify and follow I/Os from
each VM on the shared FC LUN-backed datastores for troubleshooting purposes.
In this scenario, which VMware feature Is supported by ONTAP software to accomplish this task?
- A. vSphere Cluster Services (vCLS)
- B. Virtual machine ID (VMID)
- C. Storage I/O Control (SIOC)
- D. Network I/O Control (NIOC)
正解:A
質問 # 23
You recently discovered the error message shown below in your ONTAP logs.
What should be your first action to correct this Issue?
- A. Use the wafliron command against my_data_vol to solve the inconsistency on the volume.
- B. Power cycle all the disk storage shelves that contain drives of the aggregate with the my_data_vol
volume. - C. Use the storage takeover command on the storage controller that contains my_data_vol.
- D. Determine the root cause behind the inconsistency before attempting any recovery procedure.
正解:B
質問 # 24
The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02.
Node-02 panics showing the string below.
PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess
fnmbx_instanceWorker on release 9.5P8 (C)
What has happened in this situation?
- A. While in maintenance mode, the HA_config show command was executed.
- B. While in maintenance mode, the mailbox destroy local command was executed.
- C. While in maintenance mode, the sldiag device show command was executed.
- D. While in maintenance mode, the fcadmin device_map command was executed.
正解:D
質問 # 25
A user reports that a colleague saved a file called Test.txt from a UNIX system to a multiprotocol volume.
When opening the file later from a Windows system, it was not the file that they wanted. The file that they
wanted was named TEST~1.TXT.
Which statement explains this behavior?
- A. A Snapshot copy preserved two versions of the file.
- B. Windows Volume Shadow Copy Service stored an older version of the file.
- C. UNIX name mapping updated the filename.
- D. Case Insensitivity of SMB clients caused the file to be displayed with a different name.
正解:A
質問 # 26
......
更新されたのはNetwork Appliance NS0-593問題集PDFオンラインエンジン:https://jp.fast2test.com/NS0-593-premium-file.html
NS0-593.PDFで問題解答PDFサンプル問題信頼され続ける:https://drive.google.com/open?id=1g8TSultCgbsRR69OAY_A_GaoOigGTBnB