[2024年12月最新リリース]D-PEMX-DY-23問題集でDell Server認証
最新の完璧なD-PEMX-DY-23問題集問題と解答で100%パスさせます
質問 # 15
While servicing an MX7000 chassis a system administrator logs into OME-M and receives a Chassis Mismatch error.
What should be the next step taken by the administrator?
- A. Perform firmware update
- B. Force Active/Clear configuration
- C. Reset Peer or the Local IOM
- D. Clear the configuration
正解:B
質問 # 16
What type of connection is used by QuickSync 2?
- A. LTE
- B. QuickAssist
- C. NFC
- D. Bluetooth
正解:D
質問 # 17
A server administrator is deploying a VMware vSphere cluster and configuring High Availability on a PowerEdge MX7000 modular system.
Which configuration is required?
- A. PERC MX745P
- B. Drive-assigned storage
- C. Enclosure-assigned storage
- D. SAS IOM setup in redundant mode
正解:C
質問 # 18
What are the components of the control panel of a PowerEdge MX750c sled?
- A. Power button
USB 2.0 port
micro DisplayPort
iDRAC direct status LED - B. Power button
USB 3.0 port
iDRAC micro port
iDRAC direct status LED - C. Power button
USB 3.0 port
micro DisplayPort
iDRAC direct status LED - D. Power button
USB 2.0 port
iDRAC micro port
iDRAC direct status LED
正解:B
質問 # 19
After a main board replacement, the easy restore process was not successful. A system administrator is not able to launch the Virtual Console.
What is the cause of this issue?
- A. Enterprise license is not installed.
- B. Java is not installed.
- C. ActiveX is not installed.
- D. KVM is not present.
正解:A
質問 # 20
What is the minimum OME-M version required to use ATMOS?
- A. 2.10.00
- B. 1.60.50
- C. 2.00.00
- D. 1.40.00
正解:C
質問 # 21
Which MX7000 chassis components does the Vertical Power Distribution Board power?
- A. Compute sleds
Right and Left Control Panels
Rear fans - B. IOMs
Compute sleds
Rear fans - C. IOMs
Rear fans
Front fans
正解:C
質問 # 22
A system administrator must assign six of the MX5016s drives to a single MX750c compute node.
Which assignment mode accomplishes this task?
- A. Drive-assigned storage configuration
- B. Multiple-assigned storage configuration
- C. PERC-assigned storage configuration
- D. Enclosure-assigned storage configuration
正解:A
質問 # 23
What are the correct CLI commands to configure the management IP Address on either the MX9116n or the MX5108n switches running SmartFabric OS10?
- A. interface vlan 4020
no ip address
ip address 192.168.1.10/24
no shutdown
exit
management route 0.0.0.0/0 192.168.1.1 - B. interface vlan 4020
no ip address
ip address 192.168.10.10/24
no shutdown
exit
interface mgmt 1/1/1
no shutdown
exit
management route 0.0.0.0/0 192.168.10.1 - C. interface mgmt 1/1/1
no ip address
ip address 192.168.10.10/24
no shutdown
exit
management route 0.0.0.0/0 192.168.10.1 - D. interface vlan 4020
no ip address
ip address 192.168.1.10/24
no shutdown
exit
interface mgmt 1/1/1
no ip address
ip address 192.168.1.10/24
no shutdown
exit
management route 0.0.0.0/0 192.168.1.1
正解:D
質問 # 24
Which I/O module(s) supports Full Switch and SmartFabric operating modes?
- A. MX9116 and MX7116n
- B. MX5108 and MX5016s
- C. MX9116n only
- D. MX9116n and MX5108n
正解:D
質問 # 25
During the installation of a PowerEdge MX7000, the implementation engineer notices the PSU health indicator stay on for one second, blink five times, then shut off.
What is the issue?
- A. The PSU is faulty.
- B. There is no power to the PSU.
- C. The PSU is performing firmware updates.
- D. There is a PSU mismatch.
正解:D
質問 # 26
The MX9116n FSE has two single-density QSFP28 port groups, and the default setting for these two ports is 1x 100GbE.
What other Ethernet breakout configurations are supported?
- A. 4x 10GbE
1x 40GbE
8x 25GbE
2x 50GbE - B. 4x 10GbE
1x 40GbE
4x 8 Gb
4x 32 Gb - C. 4x 10GbE
1x 40GbE
4x 25GbE
2x 50GbE - D. 4x 16 Gb
2x 32 Gb
4x 25GbE
2x 50GbE
正解:C
質問 # 27
What compute sled model best supports the following requirements?
4 Node Database Cluster Heavy transactional workload 16 Processors
24 TB of DDR4 Memory
40 TB of Disk Space Maximum of 200,000 IOPS
- A. 8 x MX750C 16 Processors
16 TB of DDR4 Memory
45 TB of Disk Space based on NVMe Drives - B. 4 x MX840C 16 Processors
24 TB of DDR4 Memory
40 TB of Disk Space based on SAS SSD Drives - C. 8 x MX740C 16 Processors
16 TB of DDR4 Memory
50 TB of Disk Space based on SAS SSD Drives - D. 4 x MX840C 16 Processors
24 TB of DDR4 Memory
40 TB of Disk Space based on NVMe Drives
正解:D
質問 # 28
What are the typical ambient inlet temperature readings that ATMOS hardware and fans support?
- A. 30 uplink configuration combination of the Top of the Rack Switch and the MX70(104°F)
- B. 15°C (59°F), 20°C (68°F), and 25°C (77°F)
- C. 25°C (77°F), 30°C (86°F), and 35°C (95°F)
- D. 20°C (68°F), 25°C (77°F), and 30°C (86°F)
正解:A
質問 # 29
A technician replaces a failed Management Module in an MX7000 chassis group. After the technician leaves the site, the administrator reports that the lead chassis is no longer able to communicate with its members.
How can OME-M be used to confirm the cabling configuration?
- A. View the health status of the lead Chassis Management Module
- B. View the health status of the lead Chassis Management ports
- C. View the topology map from the Group Lead
- D. View the I/O module topology map from the lead chassis
正解:B
質問 # 30
Which micro controller-based module allows the Management Module to communicate with all the hardware present in a PowerEdge MX7000 chassis?
- A. FReD
- B. EC
- C. iSM
- D. iDRAC
正解:A
質問 # 31
A server sled has a single mezzanine card installed in the correctly supported slot. To which IOM fabric(s) does the sled have access?
- A. Fabric A1 and Fabric A2
- B. Fabric A1 only
- C. Fabric A1 and Fabric B1
- D. Either Fabric A or Fabric B, depending on the configuration set in OME-M
正解:B
質問 # 32
A new administrator has just taken over an MX7000 Multi-Chassis Management Group and two-racks of PowerEdge servers. The previous administrator no longer works at the company and is not available.
No one knows the password for the OME-M interface and the default password is not working.
What must be used to reset the password?
- A. RACADM using a serial connection
- B. Left ear control panel.
- C. Management Module jumpers
- D. iDRAC for one of the compute sleds.
正解:C
質問 # 33
An administrator is configuring a fully populated MX5016s storage sled to be accessed by four MX740c compute sleds. Each compute sled has an H745P Jumbo PERC installed. The disks in the storage sled are evenly distributed across all compute sleds using a Drive-Assigned storage configuration.
What is the maximum number of disks that each compute sled can detect from the MX5016s?
- A. 0
- B. 1
- C. 2
- D. 3
正解:C
質問 # 34
What is the maximum supported drive configuration on a PowerEdge MX840c compute sled?
- A. 4 x 2.5" drives and 2 x 3.5" drives
- B. 6 x 3.5" drives
- C. 2 x 2.5" drives and 4 x 3.5" drives
- D. 8 x 2.5" drives
正解:D
質問 # 35
Which feature requires an iDRAC Enterprise license for an MX sled?
- A. Last Crash Screen
- B. iDRAC Service Module
- C. Storage Management
- D. Group Manager
正解:D
質問 # 36
......
最新のD-PEMX-DY-23試験問題集でEMC試験トレーニング:https://jp.fast2test.com/D-PEMX-DY-23-premium-file.html