更新されたPDF(2024年最新)実際にあるEMC D-PEMX-DY-23試験問題
検証済みのD-PEMX-DY-23試験問題集PDF[2024年最新] 成功の秘訣はFast2test
質問 # 79
What types of network shares are supported for hosting the firmware catalog for a PowerEdge MX7000 chassis?
- A. HTTP, HTTPS, FTP, and SFTP
- B. SCP, FTP, NFS, and HTTPS
- C. NFS, CIFS, HTTP, and HTTPS
- D. SMB, SFTP, NFS, and FTP
正解:C
質問 # 80
Which two main components comprise a Scalable Fabric?
- A. MX9116n and the 25GbE PTM
- B. MX7116n and the MX5108n
- C. MX9116n and the MX5108n
- D. MX9116n and the MX7116n
正解:D
質問 # 81
Which protocol(s) does Redfish use?
- A. JSON only
- B. JSON, OData, and SNMP
- C. JSON and OData only
- D. OData only
正解:C
質問 # 82
An administrator is receiving notifications about insufficient power for a PowerEdge MX7000 chassis.
The chassis is fed from two different power grids.
What is the best policy to maximize power and maintain uptime?
- A. PSU Redundancy
- B. No Redundancy
- C. Grid Redundancy
- D. PSU Pairing
正解:B
質問 # 83
A customer must assign specific VLANs to each NIC partition configured.
Which NIC supports that feature?
- A. QLogic 41232
- B. Broadcom 57504
- C. Intel XXV710
- D. Mellanox ConnectX-4
正解:B
質問 # 84
After a main board replacement, the easy restore process was not successful. A system administrator is not able to launch the Virtual Console.
What is the cause of this issue?
- A. Java is not installed.
- B. Enterprise license is not installed.
- C. KVM is not present.
- D. ActiveX is not installed.
正解:B
質問 # 85
What is a benefit of using scalable fabric architecture in the MX7000?
- A. Management of all fabrics is done from the last chassis in the fabric
- B. Management of all fabrics is done from the third fabric in the chassis
- C. Management of all servers and fabrics is done from the last chassis in the fabric
- D. Management of all servers and fabrics is done from the lead chassis
正解:D
質問 # 86
A technician is doing an initial MX7000 setup and wants to use KVM to configure the MM. KVM is not working.
What are the two causes of this issue?
(Select 2)
- A. Mouse is not connected.
- B. DP-to-DVI and DP-to-HDMI adapters are not supported.
- C. The resolution set on MM is too high.
- D. MM is going through a reset.
正解:B、D
質問 # 87
Which SmartFabric Services Engine component is responsible for managing requested changes for the specific switching node?
- A. External Fabric Manager
- B. Fabric Agent
- C. SFS Controller
正解:B
質問 # 88
What type of connection is used by QuickSync 2?
- A. Bluetooth
- B. QuickAssist
- C. LTE
- D. NFC
正解:A
質問 # 89
At the initial release of the MX7000 for a daisy-chained configuration in a multi-chassis management group (MCM)m what is the maximum number of member chassis allowed, not counting the lead chassis?
- A. 0
- B. 1
- C. 2
- D. 3
正解:B
質問 # 90
What are two considerations when adding an MX760c in a chassis running OME-M firmware earlier than v2.0?
(Select 2)
- A. If the iDRAC of the existing sleds is not at a supported level, ATMOS cannot calculate the maximum cooling.
- B. If the MX760c is not a thermally challenged system, the sled is going to run as designed.
- C. If the MX760c is a thermally challenged system, the maximum supported ambient temperature cannot be reduced.
- D. All the fans on the PowerEdge MX7000 must be Silver Grade.
正解:A、C
質問 # 91
What is a benefit of SmartFabric Services Mode?
- A. Topology validation and self-healing
- B. Load balancing for application layers
- C. Automatic detection of packet collisions
- D. Load balancing for management layers
正解:D
質問 # 92
Refer to the exhibit.
How many internal server-facing ports are available on this I/O module for the MX7000 chassis?
- A. 0
- B. 1
- C. 2
- D. 3
正解:C
質問 # 93
Where are the diagnostic LEDs located on a PowerEdge MX750c compute sled?
- A. Front of the sled after removing the top two drives
- B. Middle of the system board with the top of the cover removed
- C. Located on the back of the sled
- D. Front of the sled after removing the bottom two drives
正解:D
質問 # 94
What is the port configuration of the MX9116n FSE?
- A. 16 internal 25 GbE server facing ports
12 QSFP28-DD ports
2 100 GbE QSFP28 uplink ports
2 100 GbE QSFP28 unified ports - B. 16 internal 25 GbE server facing ports
10 QSFP28-DD ports
4 100 GbE QSFP28 uplink ports
2 100 GbE QSFP28 unified ports - C. 32 internal 25 GbE server facing ports
10 QSFP28-DD ports
4 100 GbE QSFP28 uplink ports
2 100 GbE QSFP28 unified ports - D. 32 internal 25 GbE server facing ports
12 QSFP28-DD ports
2 100 GbE QSFP28 uplink ports
2 100 GbE QSFP28 unified ports
正解:A
質問 # 95
What item is used to refer to a daisy-chained configuration of a multiple MX7000 chassis environment?
- A. Wired group
- B. Chassis group
- C. Identity group
- D. Physical group
正解:A
質問 # 96
What is the port configuration of an MX5108n switch?
- A. 8 x internal 25GbE ports
2 x 40GbE QSFP+ ports
1 x 100GbE QSFP28 port
4 x 10GbE RJ45 Base-T ports - B. 16 x internal 25GbE ports
1 x 40GbE QSFP+ port
2 x 100GbE QSFP28 ports
4 x 10GbE RJ45 Base-T ports - C. 16 x internal 25GbE ports
4 x 40GbE QSFP+ ports
2 x 100GbE QSFP28 ports
1 x 10GbE RJ45 Base-T port - D. 8 x internal 25GbE ports
1 x 40GbE QSFP+ port
2 x 100GbE QSFP28 ports
4 x 10GbE RJ45 Base-T ports
正解:D
質問 # 97
......