質問 # 18
An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment The inventory consists of:

The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb What additional component(s) is needed for this configuration?

  • A. Hot-plug power supply, 1100W - qty 1
  • B. Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters - qty 2
  • C. Hot-plug power supply, 750 W - qty 1
  • D. C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord - qty 2

正解:C


質問 # 19
What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?

  • A. Single-level cell
  • B. Write Intensive
  • C. Read Intensive
  • D. Quad-level cell

正解:C


質問 # 20
A Dell EMC PowerEdge 14G server uses Intel OPTANE DC Persistent Memory in App Direct mode. What is the minimum size DIMM supported for this type of memory?

  • A. 128 GB
  • B. 64 GB
  • C. 256 GB
  • D. 512 GB

正解:C


質問 # 21
A technician needs to change the iDRAC password on a Dell EMC PowerEdge 14G server in a lights-out datacenter. The be rebooted because it is in production. The iDRAC is configured with the default credentials How could the technician change the iDRAC password?

  • A. iDRAC Web GUI
  • B. Virtual Console; press F2 after rebooting system
  • C. OpenManage Server Administrator
  • D. SupportAssist Enterprise

正解:A


質問 # 22
A technician needs to update the IDRAC license on a Dell EMC PowerEdge R740 server from Express to Enterprise. The server has the following components:
* 2x CPUs
* 384 GB RAM
* 6x 1 TB drives
* 1x PSU
The server is connected to active AC, but it is powered down, and it needs to stay powered down No errors are presently displayed How can the technician upgrade the license?

  • A. Power on the server, then connect to the iDRAC and upgrade iDRAC license before powering down the server
  • B. The license cannot be upgraded on a single PSU system
  • C. The license cannot be upgraded because the user will not allow the server to be powered on
  • D. Connect to the iDRAC GUI and upgrade the .DRAC license while the server .s powered down

正解:B


質問 # 23
What is a characteristic of SupportAssist Enterprise on Dell EMC PowerEdge 14G servers?

  • A. Proactive, predictive, and automated support technology to enable faster resolution and reporting
  • B. Used for customers that want monitoring of fewer than 1,000 server, storage, and networking devices
  • C. Includes onsite monitoring and automated collection of system state information
  • D. Dispatches technical support from Dell for all Dell servers, storage, and networking devices

正解:C


質問 # 24
A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?

  • A. Configure servers to access the remote firmware repository
  • B. Enable the Collect System Inventory On Restart (CSIOR) attribute
  • C. Enable the Match Firmware of Replaced Part setting in the system BIOS
  • D. Install and configure a repository manager

正解:C


質問 # 25
A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC What should the technician do to verify iDRAC connectivity on each server?

  • A. iDRAC Datacenter license is installed.
  • B. iDRAC dedicated NIC port is cabled and the link light is green
  • C. iDRAC Enterprise license is installed
  • D. Ethernet port LOM1 is cabled and the link light is green.

正解:D


質問 # 26
An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.
What task should be completed to troubleshoot this issue?

  • A. Confirm the System Input Power CAP is not set to Low
  • B. Verify the new PSU is the same type and wattage rating
  • C. Set the PSU AC redundancy to 1+1
  • D. Set the PSU AC redundancy to 1+0

正解:B


質問 # 27
A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.
How can the technician find out what the error message was?

  • A. Access the Lifecycle Controller and view the last boot cycle video capture entry
  • B. Access the iDRAC and view the last boot cycle video capture entry
  • C. Reload the BIOS firmware
  • D. Export the Server profile and analyze for any POST errors

正解:B


質問 # 28
An engineer wants to fully leverage Microsoft Windows Server 2016 for TPM-based guarded host deployment of a 14G server Which BIOS settings need to be used for installing the Windows server?
A)

B)


D)

  • A. Option D
  • B. Option A
  • C. Option C
  • D. Option B

正解:C


質問 # 29
What can be done using in-band management?

  • A. Agentless discovery
  • B. Firmware and driver updates
  • C. Remote access
  • D. Network bandwidth optimization

正解:D


質問 # 30
What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?

  • A. Read Intensive
  • B. Write Intensive
  • C. Quad-level cell
  • D. Single-level cell

正解:D


質問 # 31
A technician needs to update the IDRAC license on a Dell EMC PowerEdge R740 server from Express to Enterprise. The server has the following components:
* 2x CPUs
* 384 GB RAM
* 6x 1 TB drives
* 1x PSU
The server is connected to active AC, but it is powered down, and it needs to stay powered down No errors are presently displayed How can the technician upgrade the license?

  • A. Connect to the iDRAC GUI and upgrade the .DRAC license while the server .s powered down
  • B. Power on the server, then connect to the iDRAC and upgrade iDRAC license before powering down the server
  • C. The license cannot be upgraded on a single PSU system
  • D. The license cannot be upgraded because the user will not allow the server to be powered on

正解:A


質問 # 32
A system engineer has a 14G Dell EMC Poweredge server with an amber light blinking. The engineer must pull a SupportAssist collection before calling Dell Support to evaluate what the potential problem. Use the simulator to collect and view the SupportAssist collection.

  • A. A technician wants to
  • B. Send us your suggestion for this simulation task.

正解:B


質問 # 33
......


試験には、多肢選択問題、ドラッグアンドドロップ問題、シミュレーション問題など、さまざまな問題形式が含まれています。この試験を受ける個人は、一定の時間内に合格点を取得する必要があり、認定を取得するために必要な条件です。


EMC DES-4122試験は、PowerEdgeサーバでの作業の一定の経験と、ITの概念と技術に基本的な理解力を持つプロフェッショナルを対象としています。この試験を受けることに興味のある人は、サーバ管理に強いバックグラウンドを持ち、VMwareやHyper-Vなどの仮想化技術での作業経験があることが望ましいです。

 

DES-4122問題集を無料PDFゲットせよ最近更新された問題:https://jp.fast2test.com/DES-4122-premium-file.html

DES-4122ブレーン問題集で学習ガイドには試験合格するための秘訣:https://drive.google.com/open?id=1HSdWQpNPRtfzuznkgOBXMB3Y5aEIvaIM


弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

我々の働いている時間: ( GMT 0:00-15:00 )
月曜日から土曜日まで

サポート: 現在連絡 

English Deutsch 繁体中文 한국어