正真正銘のDES-4122問題集で無料PDF問題で合格させる
結果を保証するには最新2022年10月無料で提供するDES-4122
EMC DES-4122 認定試験の出題範囲:
| トピック | 出題範囲 |
|---|---|
| トピック 1 |
|
| トピック 2 |
|
| トピック 3 |
|
| トピック 4 |
|
| トピック 5 |
|
| トピック 6 |
|
| トピック 7 |
|
| トピック 8 |
|
| トピック 9 |
|
質問 18
What are the default settings used when applying firmware and a configuration to a replaced part using the Lifecycle Controller?
- A. Firmware Allow version upgrade only
Configuration: Disabled - B. Firmware: Upgrade to latest available version
Configuration Apply always - C. Firmware: Match firmware of replaced part
Configuration Apply always - D. Firmware Disabled
Configuration Apply only if firmware match
正解: C
質問 19
Which card connects to the PCI bus, is physically smaller than a on the system board of a Dell EMC PowerEdge 14G server?
- A. OCP
- B. FPGA
- C. NDC
- D. PCIe
正解: D
質問 20
What happened on April 30, 2019?

Note: It is necessary to dose (x) the simulator window before you can select a response to this question.
- A. Option B
- B. Option D
- C. Option A
- D. Option C
正解: D
質問 21
Which rear disk drive option is available in a Dell EMC PowerEdge R740xd server?
- A. 4x 3.5" drives
- B. 2x3.5" drives
- C. 8x2 5" drives
- D. 6x2 5" drives
正解: B
質問 22
What can be done using in-band management?
- A. Network bandwidth optimization
- B. Remote access
- C. Firmware and driver updates
- D. Agentless discovery
正解: A
質問 23
How can the ePSA be accessed?
- A. VMware vSphere plug-in
- B. iDRAC
- C. OMSA
- D. Lifecycle Controller
正解: B
質問 24
You are creating a new RAID 5 storage pool on a Dell EMC PowerEdge server based on 30 x 1TB drives Which PERC model best supports this configuration?
- A. H740P
- B. H330
- C. S140
- D. H740T
正解: C
質問 25
Which type of access is known as Firmware RACADM on a Dell EMC PowerEdge server?
- A. Logging into iDRAC through Boot Manager
- B. Accessing RACADM with OpenManage software
- C. Logging into iDRAC using SSH or Telnet
- D. Accessing RACADM running the Dell Toolkit
正解: C
質問 26
A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system. What Is the cause of this Issue?

Note: It is necessary to dose (x) the simulator window before you can select a response to this question.
- A. The Virtual Console is disabled
- B. There are more than the maximum number of active sessions
- C. Operating system not installed on remote server
- D. The server has been powered down
正解: D
質問 27
A technician needs to change the iDRAC password on a Dell EMC PowerEdge 14G server in a lights-out datacenter. The be rebooted because it is in production. The iDRAC is configured with the default credentials How could the technician change the iDRAC password?
- A. OpenManage Server Administrator
- B. SupportAssist Enterprise
- C. iDRAC Web GUI
- D. Virtual Console; press F2 after rebooting system
正解: B
質問 28
An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.
What task should be completed to troubleshoot this issue?
- A. Verify the new PSU is the same type and wattage rating
- B. Set the PSU AC redundancy to 1+1
- C. Confirm the System Input Power CAP is not set to Low
- D. Set the PSU AC redundancy to 1+0
正解: A
質問 29
A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad
1Gb NIC and redundant power supplies The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC What should the technician do to verify iDRAC connectivity on each server?
- A. Ethernet port LOM1 is cabled and the link light is green.
- B. iDRAC Datacenter license is installed.
- C. iDRAC dedicated NIC port is cabled and the link light is green
- D. iDRAC Enterprise license is installed
正解: C
質問 30
An engineer needs to upgrade a Dell EMC PowerEdge R440 server from a single PSU to dual PSU configuration. There are unused PSU modules from PowerEdge R430 and R420 servers available, and they have the same wattage ratings.
What should the engineer do to complete the task?
- A. Add the PowerEdge R420 PSU modules to the PowerEdge R440
- B. Configure the PowerEdge R440 PSU with 1+1 configuration
- C. Order a new PSU specific to the existing PowerEdge R440
- D. Add the PowerEdge R430 PSU modules to the PowerEdge R440
正解: A
質問 31
You must configure a BOSS card with 2 x 120GB drives for a Dell EMC PowerEdge server. What is the only supported mode?
- A. RAID 5
- B. RAID 0
- C. Non-RAID Mirroring
- D. RAID 1
正解: B
質問 32
For security reasons, the Dell EMC PowerEdge server power button must be disabled. Use the System Setup Utility in the simulator to disable the power button. When you have finished using the simulator, click Next.
正解:
解説:
Send us your suggestion for this simulation task.
質問 33
What is a consideration when populating DIMMs with different types of persistent memory in a Dell EMC PowerEdge 14G server?
- A. LRDIMMs can be mixed only with RDlMMs
- B. NVDIMMs can be mixed only with LRDIMMs
- C. RDlMMs can be mixed only with NVDIMMs
- D. NVDIMMs cannot be mixed with RDlMMs
正解: B
質問 34
What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?
- A. OpenManage Essentials
- B. iDRAC9
- C. iSM
- D. SupportAssist Enterprise
正解: A
質問 35
When does a customer require the Service Tag of the Dell EMC PowerEdge server?
- A. First time logging in to iDRAC
- B. Obtaining warranty information
- C. Activating the OS
- D. First time accessing the BIOS
正解: A
質問 36
......
DES-4122ブレーン問題集PDF、EMC DES-4122試験問題詰合せ:https://jp.fast2test.com/DES-4122-premium-file.html
有効な問題最新版を無料で試そうDES-4122試験問題集解答:https://drive.google.com/open?id=1HSdWQpNPRtfzuznkgOBXMB3Y5aEIvaIM