最新 [2024年11月16日]D-PE-OE-23試験正確解答Dell PowerEdge Operate 2023のPDF問題 [Q96-Q118]

Share

最新 [2024年11月16日]D-PE-OE-23試験正確解答Dell PowerEdge Operate 2023のPDF問題

あなたのキャリアーを稼いで飛躍せよEMC 325問題

質問 # 96
iDRAC9 System Lockdown Mode is enabled.
In addition to the Power cap setting and System power operations, which settings can an administrator access?

  • A. Update firmware
    Lifecycle Controller
  • B. Part replacement
    Lifecycle Controller
  • C. Update firmware
    Diagnostics
  • D. Part replacement
    Diagnostics

正解:D


質問 # 97
How can the ePSA be accessed?

  • A. OMSA
  • B. iDRAC
  • C. Lifecycle Controller
  • D. VMware vSphere plug-in

正解:B


質問 # 98
A user installed OME on a PowerEdge R640 server. OME has discovered and is currently monitoring another 30 remote PowerEdge 14G servers.
Each server has the following configuration:
- 2x CPUs
- 384 GB RAM
- 6x 1TB drives in a RAID 6 virtual disk
- No hot spare drive
- PERC
- vFlash
- iDRAC9 Express license
At 9 PM on Monday evening, one of the remote servers has a disk failure but stays operational. The administrator monitoring OME does not find out about the issue until 5 PM in the following Friday. They place a support call to investigate why OME was not informed about the disk failure before then.
What is the reason for this issue not being reported to OME?

  • A. Remote servers need to have the iDRAC Enterprise license installed to be able to send alerts.
  • B. Remote servers are not configured with OME as the trap destination address. OME discovered the issue during a routing status check which is configured to run at 5 PM every Friday.
  • C. OME only updates its alert database at 5 PM every Friday.
  • D. Remote servers are not configured with OME as the trap destination address. OME was informed of the issue when remote servers sent alerts at 5 PM Friday.

正解:B


質問 # 99
A customer encounters a MEM7114 message indicating the post package repair (PPR) has failed.
What should be the next step to reach a resolution?

  • A. Replace affected DIMM.
  • B. Reseat affected DIMM.
  • C. Swap the processors.
  • D. Move A side DIMM to B side.

正解:A


質問 # 100
A technician installs a server with a network daughter card (NDC). The NDC has two 10Gb BaseT ports as well as 1Gb BaseT ports. The technician is using the correct CAT- 6 network cable and a 10Gb switch. The server reports 1Gb connections on ports 3 and 4. Ports 1 and 2 are down.
How should the technician get 10Gb connectivity?

  • A. Replace the network cables
  • B. Move the cables over to ports 1 and 2
  • C. Hard set the switch ports to 10Gb
  • D. Use different ports on the switch

正解:A


質問 # 101
A technician has a 13G system that is giving NO video to a crash cart connected to the front VGA port. The LCD is NOT reporting any errors.
The system reports 'CPU Resetting' messages sporadically in the lifecycle log. The iDRAC runs an Express license. The technician needs to most efficiently determine if the system is completing POST despite the video issue.
Which two steps should the technician take to perform this task? (Choose two.)

  • A. Connect to rear VGA port
  • B. Reduce to minimum to post
  • C. Launch the iDRAC virtual console
  • D. Hold the system identification button for 6 seconds

正解:A、B


質問 # 102
A server has a dead system board that a technician must replace. After replacing the new system board the technician finds that the user did not back up the server profile, although they did configure the Parts Replacement policy to restore the configuration and firmware revisions for any replaced parts.
After powering on the server with the new system board, the Easy Restore feature displays a window asking if the Easy restore configuration needs to be restored to the system board.
As the Parts Replacement policy had already been configured, the technician selects YES at the Easy Restore screen knowing that the parts Replacement policy will restore the remaining configurations. After powering on the server, the technician then finds that the parts not covered by Easy Restores have not been reconfigured.
What caused the reconfiguration process to stop?

  • A. The technician did not back up the server profile upon arrival and before installing the new system board
  • B. The technician forgot to move the vFlash SD card from the old system board to the new system board
  • C. Configuration data used by the Parts Replacement policy was stored in the Lifecycle Controller on the original system board
  • D. Easy Restore overrides the Parts Replacement policy

正解:C


質問 # 103
What does OBPAR allow on a PowerEdge MX750c?

  • A. Run a compute sled with maximum performance.
  • B. Boot a compute sled with only one CPU.
  • C. Run a compute sled with memory overclocking.
  • D. Boot a compute sled with reduced frequency.

正解:D


質問 # 104
A technician is sent on- site to troubleshoot a server that produced an error message during the most recent POST but then completed the POST and booted to the operating system.
The user cannot remember the specific error and no entry was made in the error tog relating to this error.
How can the technician find out what the error message was?

  • A. Export the Server profile and analyze tor any POST errors
  • B. Access the Lifecycle Controller and view the last boot cycle video capture entry
  • C. Reload the BIOS firmware
  • D. Access the iDRAC and view the last boot cycle video capture entry

正解:A


質問 # 105
A technician working with a Dell EMC PowerEdge 14G server observes the PCIe indicator turn solid amber.
What should they do to take corrective action upon checking the System Event log?

  • A.
  • B.
  • C.
  • D.

正解:C


質問 # 106
A technician needs to install the OS on a server remotely using iDRAC.
What is the minimum iDRAC license required to perform this task?

  • A. Basic
  • B. Baseboard Management Controller
  • C. Enterprise
  • D. Express

正解:C


質問 # 107
A technician builds a bootable ISO with Repository Manager, and then mounts the ISO via the iDRAC virtual console. After the updates have completed, the technician reboots the server to apply the updates. When reviewing the updates, the technician determines NOT all updates were applied.
What is causing this issue?

  • A. The iDRAC update caused virtual media disconnect.
  • B. A SUU repository must be used to update the firmware instead of the bootable ISO.
  • C. An OS was NOT installed prior to upgrading the firmware.
  • D. The firmware must be manually updated from the iDRAC.

正解:B


質問 # 108
A technician needs to add a device to SupportAssist Enterprise. Policy requires that no additional software be installed on the server OS.
In addition to Username and Password, what information is required to add the device?

  • A. IP address for Dell TechDirect
  • B. IP address fir OpenManage Server Administrator
  • C. IP address or hostname for the server OS
  • D. IP address or hostname for the iDRAC

正解:D


質問 # 109
Which processor configuration is used by the Dell EMC PowerEdge R6525 server?

  • A. 4 socket Intel
  • B. 2 socket Intel
  • C. 4 socket AMD
  • D. 2 socket AMD

正解:D


質問 # 110
A technician has replaced a network daughter card (NDC) with a different, supported NDC.
Using the Lifecycle Controller, what can they do to verify that the new NDC is present?

  • A. View Factory Shipped Inventory from Hardware Inventory
    Select Import NDC MIB
  • B. Verify Hardware Inventory License has been imported
    Verify Current Inventory form Hardware Inventory
  • C. View System Information from System Setup > Advanced Hardware Configuration > System BIOS Select Configure NDC in Device Settings
  • D. View Current Inventory from Hardware Inventory
    Verify Collect System Inventory on Restart Option (CSIOR) is enabled

正解:D


質問 # 111
What is a valid password option available from the iDRAC9 Unique ID feature?

  • A. Secure Default
  • B. Legacy Generated
  • C. Randomly Generated
  • D. Encryption Default

正解:C


質問 # 112
What happens when the Hardware Root of Trust fails to validate the BIOS?

  • A. The server continues running and logs a critical error in the system event log.
  • B. Automated BIOS Recovery process recovers the BIOS from the DUP saved in the control panel.
  • C. Boot Guard switches over to the backup BIOS and logs a warning in the system event log.
  • D. The server shuts down and logs a critical error in the system event log.

正解:D


質問 # 113
A server is being up as a VMware ESXi host. A technician needs to install the OS on an internal SD card. They install the SD card. However, during OS installation, the SD card is not visible.
What should the technician do to fix the issue?

  • A. Format the SD card with an EXT3 partition before installation
  • B. Move the SD card from slot 2 to slot 1
  • C. Enable the SD card in the BIOS Settings
  • D. Use Lifecycle Controller to install the SD card

正解:C


質問 # 114
How can a technician know whether IDRAC9 System Lockdown mode is enabled?

  • A. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC is disabled when the server boots
  • B. Lockdown activation message in red box in the iDRAC web GUI Access to LCC is disabled when the server boots
  • C. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC requires a password when the server boots
  • D. Lockdown activation message in red box in the iDRAC web GUI Access to LCC requires a password when the server boots

正解:B


質問 # 115
A new server has 128 GB of RAM and three 1 TB drives. After creating a RAID 5 array with the three internal drives on the system, a technician boots to the Lifecycle Controller to install Windows Server
2016. When the technician tries to select an install location, Windows displays an error message that states that it cannot be installed to that location.
What should the technician do to resolve this issue?

  • A. Bring up the command prompt by pressing shift F10 and use the disk part to clean the disk
  • B. Delete the array and use the Lifecycle Controller to configure the array
  • C. Change the boot mode from BIOS to UEFI
  • D. Verify that the license for installing an OS to a virtual disk is installed

正解:C


質問 # 116
A technician replaces a faulty system board on a server. In addition to powering on the system, what step must the technician take to install the correct service tag?

  • A. Type asset <asset tag> to change the asset tag
  • B. Login in to the iDRAC
  • C. Press F11 to start the Boot Manager
  • D. When prompted by Easy Restore, press Y to restore the Service Tag, license, and diagnostics information

正解:D


質問 # 117
A technician tries to power on a server but nothing happens when they press the power button. The status LEDs on both PSUs are green. The technician is able to connect to the iDRAC to review the System Event Logs and discovers that PSU2 has failed.

  • A. Cycle the AC power
    Reset the NVRAM
  • B. Reboot the server
    Test one PSU at a time
  • C. Cycle the AC power
    Test one PSU at a time
  • D. Reboot the server
    Reset the NVRAM

正解:C


質問 # 118
......

正真正銘のベスト資料はD-PE-OE-23オンライン練習試験:https://jp.fast2test.com/D-PE-OE-23-premium-file.html


弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

我々の働いている時間: ( GMT 0:00-15:00 )
月曜日から土曜日まで

サポート: 現在連絡 

English Deutsch 繁体中文 한국어