あなたを合格させるD-PE-OE-23お手軽に試験合格リアルD-PE-OE-23練習問題集で更新されたのは2024年11月06日 [Q131-Q149]

Share

あなたを合格させるD-PE-OE-23お手軽に試験合格リアルD-PE-OE-23練習問題集で更新されたのは2024年11月06日

2024年最新の実際に出ると確認されたで無料EMC D-PE-OE-23試験問題

質問 # 131
A technician has a 13G system that is giving NO video to a crash cart connected to the front VGA port. The LCD is NOT reporting any errors.
The system reports 'CPU Resetting' messages sporadically in the lifecycle log. The iDRAC runs an Express license. The technician needs to most efficiently determine if the system is completing POST despite the video issue.
Which two steps should the technician take to perform this task? (Choose two.)

  • A. Hold the system identification button for 6 seconds
  • B. Reduce to minimum to post
  • C. Launch the iDRAC virtual console
  • D. Connect to rear VGA port

正解:B、D


質問 # 132
A technician is configuring the server to boot to the Internal Dual SD Module.
Which BIOS boot option should the technician select?

  • A. Hard Drive C
  • B. Integrated NIC
  • C. vFlash Media
  • D. DVD-ROM

正解:C


質問 # 133
A technician has a server with the following memory configuration:
- Sixteen 4 GB dual-rank DIMMs
- 8 GB available to the OS
The workload intended for the server required the memory configuration to protect against some errors.
Now the technician must deploy for a different workload that requires access to all available memory.
Which setting should the technician change to make all memory available to the system?

  • A. Mirrored
  • B. Sparing
  • C. Performance
  • D. Optimizer

正解:A


質問 # 134
A server has two 1100w power supplies. The system needs to enable or disable power supplies dynamically depending on power needs. Power Supply 2 needs to be main power supply.
Which two settings should the technician change? (Choose two.)

  • A. Set Power Cap to 1100w for the system
  • B. Enable Power Factor Correction
  • C. Set Primary Power Supply to PSU 2
  • D. Enable Hot Spare for power supplies
  • E. Set Default Power Supply to PSU 2

正解:C、D


質問 # 135
A technician working with a Dell EMC PowerEdge 1 take corrective action?

  • A. Check the LCC Log
    Check PSU LED
    Reseat the PSU
  • B. Check the System Event Log
    Check PSU LED
    Do a virtual reseat of the iDRAC
  • C. Check the System Event Log
    Check PSU LED
    Reseat the PSU
  • D. Check the LCC Log
    Check PSU LED
    Reseat the CPU

正解:B


質問 # 136
What are the diagnostic indicators on the left control panel of a Dell PowerEdge 16G server?

  • A. Electrical indicator, Temperature indicator, Memory indicator, and PSU indicator
  • B. Quick Sync 2 indicator, System ID indicator, PSU Indicator, and iDRAC direct indicator
  • C. Drive indicator, Memory indicator, iDRAC direct indicator, and PCIe indicator
  • D. Drive indicator, Electrical indicator, Temperature indicator, and Memory indicator

正解:D


質問 # 137
A system board was replaced. After the replacement, the system will NOT boot into Windows and gives the error 'No boot device found'. Virtual disks are seen and optimal.
What action should a technician take to resolve this issue?

  • A. Make sure that the iDRAC license was imported
  • B. Reseat the RAID chain
  • C. Insert the Windows media to fix the MBR
  • D. Change the boot settings from BIOS to UEFI

正解:D


質問 # 138
A system administrator is trying to connect to iDRAC Direct. At what port blink frequency is the USB port activity confirmed?

  • A. Four per second
  • B. Eight per second
  • C. Two per second
  • D. One per second

正解:A


質問 # 139
A technician needs to deploy a server into production. The technician needs to verify that the firmware levels match corporate policy before putting the server on the business network.
Which two methods should the technician use to verify the firmware version of iDRAC and BIOS?
(Choose two.)

  • A. Use the OMSA DVD that came with the server to view Current Drivers and Firmware
  • B. Use the Lifecycle Controller and navigate to Firmware Update to view current versions
  • C. SSH into the iDRAC and run the command racadm system config to view current firmware
  • D. Log into the iDRAC web interface to view Server Information
  • E. Scroll through the menus on the LCD panel to view the BIOS and iDRAC firmware levels

正解:C、E


質問 # 140
A technician is setting up a previously used server. Upon power up, the PERC alerts them to the presence of a foreign configuration. In the iDRAC storage section, the technician checks Foreign View.
The foreign array configuration is the same as the configuration needed for the new project.
What is a recommended way to prepare the disks for the new project?

  • A. Access the Ctrl+R utility, clear the foreign configuration and set up array as needed
  • B. Format the foreign configuration and clear the controller configuration
  • C. Import the foreign configuration and perform a full initialization
  • D. Edit the foreign configuration and set it to Ready

正解:A


質問 # 141
A company's servers were ordered with iDRAC Enterprise with vFlash. The server profile was backed up after the first boot. Changes have been made to the server BIOS settings and firmware versions, which have resulted in many performance issues.
What is the most efficient way for the technician to address the performance issues?

  • A. Restore system profile using the iDRAC or Lifecycle Controller
  • B. Run the racadm racresetcfg command to reset all server settings
  • C. Upload the approved corporate firmware versions from the file share
  • D. Reboot the server to F10 and perform System Repurpose/Retire

正解:A


質問 # 142
A server needs to be configured with a six disk RAID 10 using 3 TB drives.
What should be the available array size in this configuration?

  • A. 6TB
  • B. 12TB
  • C. 4TB
  • D. 9TB

正解:D


質問 # 143
A technician needs to update the iDRAC firmware from a USB key on a which cannot be rebooted.
What does the technician need to do to perform the update?

  • A. Access the Lifecycle Controller, select Update and Rollback, select USB as the Location Type and select the iDRAC firmware
  • B. Access the iDRAC, select System Update, select local as the Location Type, navigate to the USB key and select the iDRAC firmware and click the Reboot button
  • C. Access the Lifecycle Controller, select iDRAC Settings, Select Update then select the iDRAC firmware
  • D. Access the iDRAC, select System Update, select local as the Location Type, navigate to the USB key and select the iDRAC firmware

正解:D


質問 # 144
A technician in Portland, Oregon has been asked to update the firmware on a server in Omaha, Nebraska. They will use an NFS server also located in Nebraska for serving patches that have been vetted by their security teams.
What two pieces of information does the technician need in order to access the NFS patch server from the Lifecycle Controller or iDRAC? (Choose two.)

  • A. Share name
  • B. CHAP authentication credentials
  • C. IP address or hostname
  • D. Username and password

正解:A、D


質問 # 145
A user installed OME on a PowerEdge R640 server. OME has discovered and is currently monitoring another 30 remote PowerEdge 14G servers.
Each server has the following configuration:
- 2x CPUs
- 384 GB RAM
- 6x 1TB drives in a RAID 6 virtual disk
- No hot spare drive
- PERC
- vFlash
- iDRAC9 Express license
At 9 PM on Monday evening, one of the remote servers has a disk failure but stays operational. The administrator monitoring OME does not find out about the issue until 5 PM in the following Friday. They place a support call to investigate why OME was not informed about the disk failure before then.
What is the reason for this issue not being reported to OME?

  • A. Remote servers are not configured with OME as the trap destination address. OME was informed of the issue when remote servers sent alerts at 5 PM Friday.
  • B. OME only updates its alert database at 5 PM every Friday.
  • C. Remote servers are not configured with OME as the trap destination address. OME discovered the issue during a routing status check which is configured to run at 5 PM every Friday.
  • D. Remote servers need to have the iDRAC Enterprise license installed to be able to send alerts.

正解:C


質問 # 146
A technician is investigating a server that is reporting that the Lifecycle Controller is disabled during the power-on procedure.
After checking that the system is displaying no other errors, how can the technician re-enable the Lifecycle Controller?

  • A. Reboot the server and press Ctrl+L during the power on procedure
    At the prompt type "LCC-enable" Select save and reboot the server
  • B. Enter the iDRAC GUI
    Select iDRAC Settings > Lifecycle Controller
    Check the Enable option and then power cycle the server
  • C. Access the System Setup utility
    Select iDRAC Settings and then select Lifecycle Controller
    Check the Enable option, save, and reboot the server
  • D. Reboot the server
    Press F10 during power up and access the Lifecycle Controller GUI
    Select Power On Messages, select Enable, and reboot the server

正解:C


質問 # 147
What happens when the Hardware Root of Trust fails to validate the BIOS?

  • A. The server shuts down and logs a critical error in the system event log.
  • B. Boot Guard switches over to the backup BIOS and logs a warning in the system event log.
  • C. The server continues running and logs a critical error in the system event log.
  • D. Automated BIOS Recovery process recovers the BIOS from the DUP saved in the control panel.

正解:A


質問 # 148
A technician has a server in production. The iDRAC SEL log indicates a possible issue with DIMMs A1 and A2. Firmware is up to date.
What is the most efficient way to troubleshoot this issue?

  • A. Swap DIMMs A1 and A2 to A3 and A4
  • B. Swap DIMMs A1 and A2 to B1 and B2
  • C. Reseat DIMMs A1 and A2
  • D. Swap DIMMs A1 and A2 to B1 and B3

正解:C


質問 # 149
......

D-PE-OE-23リアル試験問題解答は無料:https://jp.fast2test.com/D-PE-OE-23-premium-file.html


弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

我々の働いている時間: ( GMT 0:00-15:00 )
月曜日から土曜日まで

サポート: 現在連絡 

English Deutsch 繁体中文 한국어