[2023年03月08日] 完全版最新の問題集でPDFで最新HPE0-S60試験問題と解答
無料で使えるHPE0-S60試験問題集で100%合格できる試験簡単に合格させるFast2test
質問 33
Match each HPE OneView network type with its definition.
正解:
解説:

質問 34
Your customer plans to deploy ESXi systems to HPE Synergy and HPE ProLiant servers using HPE OneView for VMware vCenter Server.
Which statement about HPE OneView for VMware vCenter Server functionality is true for this environment?
- A. HPE ProLiant servers need an HPE OneView for VMware vCenter Server license for full functionality
- B. HPE Synergy requires HPE Composer 2 for full functionality of HPE OneView for VMware vCenter Server
- C. Only systems managed using HPE Oneview can use HPE Oneview for VMware vCenter Server functionalities
- D. Individual systems can be added to HPE OneView for VMware vCenter Server through an ILO management processor
正解: A
質問 35
Your customer plans to setup an HPE Synergy solution based on SY480 Gen10 compute nodes with the following connectivity options - SAS connectivity installed in the first fabric - FC connectivity Installed In the second fabric - Ethernet connectivity installed in the third fabric.
Which statement regarding this setup is true?
- A. Interconnect modules that provide SAS connectivity should be moved to the third fabric
- B. Each compute node must have at least 768GB of memory installed
- C. Compute nodes must have a second CPU installed to access the second fabric.
- D. Each interconnect module in each fabric must be properly licensed in HPE OneView
正解: B
質問 36
Which statement about a new HPE SimpliVity deployment is true?
- A. All new HPE SimpliVity models are based on mid CPUs
- B. A new HPE SimpliVity node can be a member of multiple dusters
- C. New HPE SimpliVity deployments gives customer flexible choice of hypervisor
- D. AM new HPE SimpliVity models are software optimized
正解: C
質問 37
Refer to the exhibit.
Which statement about this logical interconnect group is true?
- A. The master modules are located in the interconnect bays 2 and 5
- B. Both master modules are located in the same HPE S ynergy frame
- C. To use interconnect bay set 3, all compute nodes must be half-height
- D. For the given downlink speed, the maximum number of frames is reached
正解: B
質問 38
An administrator tries to open iLO interlace from HPE OneView Instead of being automatically logged in a login prompt displays Where should you start the troubleshooting process?
- A. At HPE OneView Interface to verify whether the iLO processor is disabled
- B. At the iLO interface to verify whether the SSO certificate is removed from an iLO.
- C. At the iLO interface to verify whether the ILO Advanced license is properly applied
- D. At HPE OneView Interface to verify whether the server is In the maintenance mode
正解: C
質問 39
Your customer plans to deploy HPE OneView for VMware vCenter Server together with HPE Storage Integration Pack for VMware vCenter. The customer wants to use them to manage HPE Synergy Gen10 compute modules. HPE ProLiant Gen 10 servers and an MSA array.
Which statement about compatibility of the existing environment with the planned software components is true?
- A. HPE OneView for VMware vCenter Server does not support standalone HPE ProLiant servers
- B. Both HPE Synergy Gen10 full-height compute module plugins will require a license
- C. HPE Storage integration Pack for VMware vCenter does not support MSA arrays
- D. To use the required plugins HPE ProLiant Gen10 systems must be managed using HPE OneView
正解: A
質問 40
What is a limitation when creating a server profile?
- A. It is not possible to create shared volumes on demand through a server profile
- B. ILO management is limited to the integration with Active Directory or LDAP
- C. Administrator cannot define more than 8 connections within a server profile
- D. BIOS settings can be changed only when UEFI optimized is selected as boot mode
正解: B
質問 41
Your customer reports mat an external FC boot volume for Windows server is visible four times in the Disk Management 1 online and 3 offline.
What should you do to resolve this issue?
- A. Remove the offline disks using array management tools
- B. Remove the offline disks using Windows Disk Management
- C. Install and configure MPIO on me Windows system
- D. Disable deduplication for this volume at the array level
正解: C
質問 42
You plan to configure a Link Aggregation Group (LAG) for two connections within a server profile for a compute node running an ESXI system.
What is required from the VMware side to enable LAG?
- A. Load balancing cluster
- B. Dedicated VMKernel port
- C. vSphere Standard license
- D. Virtual Distributed Switch
正解: B
質問 43
Your customer wants to compare HPE Superdome Flex with HPE Superdome Flex 280.
Which statement about these two systems is true?
- A. Only HPE Superdome Flex 280 can support multiple nPars
- B. Only HPE Superdome Rex 280 can be managed using HPE OneView
- C. Only HPE Superdome Flex supports HPE Persistent Memory
- D. Only HPE Superdome Flex supports 32 sockets and 48TB of memory
正解: B
質問 44
Your customer plans to add four HPE Synergy frames to an existing management ring Ail installed frames are equipped with two 2-port FLM modules, while new frames will be equipped with 4-port FLM modules.
Which statement about mixing different FLM modules is true?
- A. A management ring with mixed FLM modules cannot have more than 12 frames
- B. A management ring can contain mixed frame link module configurations
- C. Existing 2-port FLM modules must be replaced with 4-port FLM modules
- D. Mixing different FLM modules is allowed if all of them have the same firmware version
正解: A
質問 45
Your customer reports that they cannot deploy HPE Synergy compute nodes using HPE OneView for VMware vCenter Server (HPE OV4VC).
What should you check during troubleshooting process?
- A. If vCenter Server is licensed in the HPE Oneview interface
- B. If HPE OneView credentials are added in vCenter Server
- C. If the HPE Oneview instance Is integrated with HPE OV4VC.
- D. If an compute nodes are added to the vCenter Server
正解: D
質問 46
Match HPE Superdome Flex system with its specific feature.
正解:
解説:
質問 47
Which tool can be used to evaluate me health of an HPE Oneview appliance before proceeding with an appliance updated.
- A. HPE Composer Maintenance Console
- B. HPE OneView Global Dashboard
- C. HPE OneView Update Readiness Checker
- D. HPE OneView Firmware Compliance Report
正解: A
質問 48
Match each HPE Synergy logical component with the definition.
正解:
解説:
質問 49
After deploying HPE Superdome Flex 280 you need to check Core Analysis Engine (CAE) Log.
Click the appropriate section in the HPE Superdome Flex 280 management interface that will allow you to complete this task.
正解:
解説:
質問 50
Match HPE SimpliVity team with the definition.
正解:
解説:
質問 51
A logical interconnect group can span on multiple HPE Synergy frames for which interconnect type?
- A. HPE Synergy 12 Gb SAS Connection Module
- B. HPE Virtual Connect SE 100 Gb F32 Module tor Synergy
- C. HPE virtual Connect SE 32 Gb FC Module for Synergy
- D. Brocade 32GB Fibre Channel Switch Module for HPE Synergy
正解: B
質問 52
Click the option that will allow you to change the ESXI image used In an OS Deployment Plan.
正解:
解説:
質問 53
Your customer has a logical enclosure configured using a angle HPE Synergy frame with the following configuration
- two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- two HPE Synergy Virtual Connect SE 32Gb FC Modules -12 HPE Synergy 480 Gen10 Plus compute nodes with appropriate mezzanine cards They plan to add a new HPE Synergy frame to an existing logical enclosure with the following configuration
- two HPE Synergy Virtual Connect SE 32Gb FC Modules
- two HPE Synergy 20Gb interconnect Link Modules
- Eight HPE Synergy 480 Gen 10 Plus compute nodes with appropriate mezzanine cards Which statement about the planned configuration change is true?
- A. Four compute modules must be moved to the second frame to balance the configuration
- B. The two HPE Synergy 20Gb interconnect Link Modules must be replace with the 50Gb option
- C. The HPE Synergy virtual Connect SE 32Gb FC Modules from both frames should be stacked
- D. A license for an extended logical enclosure must be added to HPE OneView through GUI
正解: C
質問 54
Your customer plans to deploy VMware ESXi 7 0 U2 and they are looking for a hardware platform mat wilt allow them to use up to 24 TB of physical memory.
Which HPE compute system meets this customer's requirements?
- A. HPE ProLiant DL380 Gen 10 Plus
- B. HPE Synergy 480 Gen10 Plus
- C. HPE ProLiant DL560 Gen10
- D. HPE Superdome Flex 280
正解: A
質問 55
Your customer needs to move an application from an HPE Synergy 480 Gen10 Compute Module to an HPE Synergy 660 Gen 10 Compute Module. The 480 has a switch that has been manually zoned outside of HPE OneView.
What must the customer do before migrating the application?
- A. Edit the server profile and change server hardware type
- B. Create a new server profile template and apply to the new hardware
- C. Copy the server profile and assign the clone to the new hardware
- D. Migrate the application to a Logical JBOD and connect it to the new server
正解: A
質問 56
Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.
What must be done to enable dedicated FC connectivity for this HPE Synergy frame?
- A. For VC-FC modules, all of server facing ports must be property licensed.
- B. A second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.
- C. SAS switches must be moved to second fabric and FC modules Installed in the first one.
- D. For Brocade switches, a logical interconnect group must be created in HPE OneView.
正解: C
質問 57
......
HP HPE0-S60 認定試験の出題範囲:
| トピック | 出題範囲 |
|---|---|
| トピック 1 |
|
| トピック 2 |
|
| トピック 3 |
|
| トピック 4 |
|
| トピック 5 |
|
| トピック 6 |
|
無料で試せるHPE0-S60試験問題HPE0-S60実際の無料試験問題:https://jp.fast2test.com/HPE0-S60-premium-file.html
検証済みのHPE0-S60問題集と82格別な問題:https://drive.google.com/open?id=12EtrhVXJ6MFH7jqWUCim9ptYzJCXM6_H