有効なNS0-162テスト解答Network Appliance NS0-162試験PDF問題を試そう [Q43-Q67]

Share

有効なNS0-162テスト解答Network Appliance NS0-162試験PDF問題を試そう

Network Appliance NS0-162認定リアル2024年最新の模擬試験合格させます


NS0-162試験は、NetAppストレージシステムを管理するために必要なスキルや知識を検証する包括的な認定資格です。ストレージアーキテクチャやデータ管理に深い理解を持つことが求められる厳しい試験です。試験に合格するには、NetAppストレージシステムでの実務経験が必要です。

 

質問 # 43
Click the Exhibit button.
A customer has zoned switches to a host, but the host cannot see the LUNs.
Referring to the exhibit, what needs to be done to make the LUNs visible to the host?

  • A. The customer should remove the switches and directly connect the host to the controller ports.
  • B. Ports on tme-a700 nodes 1 and 2 should have the fc_nvme protocol removed.
  • C. Zoning should be changed to use the 20:06:d0:39:ea:05:03:a3 and 20:08:d0:39:ea:05:03:a3 WWPNs.
  • D. Zoning should be changed to use the 50:0a:09:81:80:d2:c3:b8 and 50:0a:09:81:42:c2:b9 WWPNs.

正解:C


質問 # 44
A customer has a 2-node AFF A220 cluster and needs to enable the FC protocol. The onboard UTA2 ports are configured for 10Gbps Ethernet. In this scenario, what are two different methods to use FCP over the UTA2 ports? (Choose two.)

  • A. Change the existing UTA2 ports from 10 Gbps speed to 8 Gb speed.
  • B. Swap the Ethernet transceivers in the UTA2 ports for 1Gbps transceivers, and configure the ports as target ports.
  • C. Swap the Ethernet transceivers in the UTA2 ports for FC transceivers, and configure the ports as target ports.
  • D. Connect onboard UTA2 ports to a Nexus switch and enable FCP.

正解:C、D


質問 # 45
Auditing has been enabled and configured on your ONTAP storage system. You have also created audit policies to monitor files and folders. Auditing has been running for over six months. You want to ensure that there have been no improper file access attempts.
How would you accomplish this task?

  • A. Use the Active IQ Web site to read EVTX files.
  • B. Use Microsoft System Center to read EVTX files.
  • C. Import EVTX files into Microsoft SQL.
  • D. Import EVTX files Into Microsoft Event Viewer.

正解:D


質問 # 46
Which configuration Is supported using NetApp's All SAN Array (ASA)?

  • A. 2-node cluster
  • B. 24-node cluster
  • C. single node cluster
  • D. 12-node cluster

正解:A


質問 # 47
Click the Exhibit button.

Referring to the exhibit, whi ch LIF role is required to copy to cloud with this NetApp Data Availability Services (NDAS) solu tion?

  • A. inter cluster
  • B. data
  • C. node management
  • D. cluster

正解:A


質問 # 48
You have a 50 TO FlexGroup volume that is serving NFSv3 on a FAS8300 HA pair that Is running ONTAP 9.8 software of files. A Linux du command runs for days to count files.
In this scenario, which native ONTAP feature will report real-time file counts?

  • A. Quality of Service
  • B. File System Analytics
  • C. volume autosize
  • D. Logical Space Reporting

正解:C


質問 # 49
Exhibit.

You recently added a new ESXi host to your VMware vSphere cluster. However, you cannot mount any of the existing NFS datastores to the host. Referring to the exhibit, which action solves the problem?

  • A. Enable Kerberos in the export policy.
  • B. Add HOST 3's IP address to the NFS export policy.
  • C. Add SMB/CIFS to the access protocols.
  • D. Add NFSv4 to the access protocols.

正解:B


質問 # 50
Exhibit.

You have an SVM-DR relationship as shown in the exhibit. You are given a new requirement to use SnapMirror Synchronous (SMS) for the data volumes In NFS-SVM-01.
In this scenario, which solution Is supported to enable SMS in ONTAP 9.8 software?

  • A. Set up new SM-S relationships from the FAS2720 to a new destination.
  • B. Modify the existing SVM-DR policy to use sync mode.
  • C. Set up new SM-S relationships from the AFF A220 to a new destination.
  • D. Set up NetApp Cloud Sync with a cloud broker in AWS to replicate to a new destination.

正解:D


質問 # 51
Which type of SVM presents a cluster as a single manageable entity?

  • A. system SVM
  • B. node SVM
  • C. cluster SVM
  • D. admin SVM

正解:D


質問 # 52
Your company wants their newly Installed ONTAP system to automatically send telemetry data to NetApp to provide early notification of any security risks, bug fixes, and ONTAP updates. Furthermore, In case of hardware failures, a support case should be opened automatically at NetApp.
Which two NetApp components satisfy the requirements? (Choose two.)

  • A. Cloud Insights
  • B. Active IQ Unified Manager
  • C. Active IQ
  • D. ONTAP AutoSupport

正解:A、B


質問 # 53
Exhibit.

After an ONTAP upgrade, you notice that several cluster LIFs are not on their home ports as shown in the exhibit.
Which LIF option would change this outcome?

  • A. the data-protocol option
  • B. the subnet-name option
  • C. the failover-policy option
  • D. the auto-revert option

正解:D

解説:
Explanation
The auto-revert option determines whether a LIF automatically reverts to its home port after a failover event.
If this option is set to true, the LIF will revert to its home port when it becomes available. If this option is set to false, the LIF will remain on the failover port until manually reverted. In this scenario, the cluster LIFs are not on their home ports after an ONTAP upgrade, which might have triggered a failover event. Therefore, setting the auto-revert option to true would change this outcome and ensure that the LIFs return to their home ports after the upgrade. References :- network interface modify, Verify all LIFS are on home ports after ONTAP upgrade


質問 # 54
Click the Exhibit button.
You have an ONTAP cluster that is running a FlexGroup that is serving SMB data out to various users. One of the users receives an error when trying to modify an existing file.
What is the cause of the problem?

  • A. The FlexGroup is full
  • B. The FlexGroup is offline
  • C. The aggregate is full
  • D. The constituent is full

正解:D


質問 # 55
All SMB users are reporting that their network share performance Is slow on a new NetApp FAS500f HA pair. You determine that the users have converged network adapters (CNAs) with flow control enabled and no option to disable.
In this scenario, which two flow control settings are recommended on the NetApp ONTAP physical ports? (Choose two.)

  • A. Enable flow control end-to-end on cluster network ports.
  • B. Disable flow control end-to-end on data network ports.
  • C. Disable flow control end-to-end on cluster network ports.
  • D. Enable flow control end-to-end on data network ports.

正解:B、C


質問 # 56
You created a thick-provisioned NAS volume. You receive an alert that the snapshot reserve is full.
In this scenario, which two actions will solve this problem? (Choose two.)

  • A. Delete Snapshot copies.
  • B. Increase the snapshot reserve percentage.
  • C. Increase the fractional reserve.
  • D. Decrease the volume size.

正解:A、B


質問 # 57
You are planning an installation of a new stack of shelves to an HA pair and need to locate empty SAS ports...
In this scenario, which tool would you use to accomplish this task remotely?

  • A. Interoperability Matrix Tool
  • B. ONTAP System Manager
  • C. Active IQ Web site
  • D. Hardware Universe

正解:A


質問 # 58
You have deployed an ONTAP cluster and want to add protocol licenses. In this scenario, which management tool accomplishes this task?

  • A. NetApp Cloud Manager
  • B. Active IQ Config Advisor
  • C. Active IQ Unified Manager
  • D. ONTAP System Manager

正解:D

解説:
Explanation
ONTAP System Manager is a web-based graphical user interface (GUI) that enables you to manage and monitor your ONTAP cluster. You can use ONTAP System Manager to add protocol licenses to your cluster by following a simple and easy workflow. The other management tools are not designed for adding protocol licenses to an ONTAP cluster. NetApp Cloud Manager is a cloud-based service that helps you deploy and manage NetApp cloud data services. Active IQ Unified Manager is a software application that provides performance monitoring and health management for ONTAP clusters. Active IQ Config Advisor is a tool that scans and validates the configuration of NetApp storage systems and hosts. References :- Configure ONTAP on a new cluster with System Manager, ONTAP System Manager overview, NetApp Cloud Manager overview, Active IQ Unified Manager overview, Active IQ Config Advisor overview


質問 # 59
The source NAS volume of a SnapMirror relationship is unavailable due to networking issues at your organization's primary data center. You want to make the destination NAS volume writable so that clients are able to access their data.
Which two steps do you need to take to solve the issue? (Choose two.)

  • A. Use the volume mount command to mount the NAS volume In the NFS namespace.
  • B. Break the SnapMirror relationship using the snapmirror break command from the source cluster.
  • C. Break the SnapMirror relationship using the snapairrcr break command from the destination cluster.
  • D. Delete the SnapMirror relationship from the destination cluster.

正解:A、C

解説:
Explanation
To make the destination NAS volume writable, you need to break the SnapMirror relationship using the snapmirror break command from the destination cluster, and then use the volume mount command to mount the NAS volume in the NFS namespace. Breaking the SnapMirror relationship will make the destination volume read/write and allow clients to access the latest Snapshot copy. Mounting the volume in the NFS namespace will make the volume visible to the clients and enable them to access the data. The other options are not correct because:
Deleting the SnapMirror relationship from the destination cluster will not make the destination volume writable, but rather remove the relationship configuration and history. This will prevent future resynchronization or updates of the relationship.
Breaking the SnapMirror relationship using the snapmirror break command from the source cluster will not work, because the source cluster is unavailable due to networking issues. The command must be run from the destination cluster. References :- Break the SnapMirror relationship, Mount a volume in the namespace


質問 # 60
An administrator has added two new hosts in an FC connected virtual environment. However, no existing datastores or LUNs are visible to these two new hosts even after a rescan.
In this scenario, which two statements are correct? (Choose two.)

  • A. Verify that correct zoning is in place between the hosts and storage.
  • B. Verify that the LUNs are online and created with the correct OS type.
  • C. Verify that FC is licensed on the ONTAP cluster.
  • D. Verify that the host initiators are added to the correct igroups.

正解:A、D


質問 # 61
Exhibit.
The availability of the remote cluster in the peering relationship shows "Partial."

Referring to the exhibit, what is the reason for this status message?

  • A. The Intercluster LIFs on the local cluster are unavailable and not able to communicate to the remote cluster.
  • B. The remote cluster does not have its cluster license applied properly.
  • C. The local cluster is unable to authenticate successfully to the remote cluster.
  • D. Some nodes in the local cluster are not able to contact some or all nodes in the remote cluster.

正解:D

解説:
Explanation
The availability of the remote cluster in the peering relationship shows "Partial" only if some nodes in the local cluster are not able to contact some or all nodes in the peer cluster1. This means that there is a network connectivity issue between some of the intercluster LIFs on the local and remote clusters. This can affect the data transfer and API communication between the clusters. The other options are not correct because they would result in different availability statuses, such as Unavailable, Pending, or Unidentified1. References
:- cluster peer show, Cluster peering issues after upgrade to ONTAP 9.11.1, Output of "cluster peer health show" intermittently displays "session_reachable" for data ping


質問 # 62
A node fails on an HA configuration. A successful failover occurs, but your clients that are using the SMB protocol complain that they are not able to access their data.
In this scenario, what caused the problem?

  • A. The disk ownership did not transfer correctly.
  • B. The surviving node is not licensed for CIFS.
  • C. The quota for the qtree has been reached.
  • D. One of the cluster Interconnect ports on the surviving node failed.

正解:B


質問 # 63
You want to enable a management LIF to restrict NTP to the 192.168.1.0/24 subnet.
In this scenario, which two actions are required to accomplish this task? (Choose two.)

  • A. Assign a policy to the management LIF.
  • B. Create a firewall policy.
  • C. Assign a policy to the NTP server.
  • D. Create a failover policy.

正解:A、B


質問 # 64
After deploying an ONTAP 9.8 cluster, you want to disable the unused Ethernet ports. In this scenario, which two methods would accomplish this task? (Choose two.)

  • A. Use Active IQ Unified Manager.
  • B. Use the command line interface.
  • C. Use Active IQ Config Advisor.
  • D. Use ONTAP System Manager.

正解:B、D


質問 # 65
Click the Exhibit button.
Referring to the exhibit, what happens to the space in the volume if the Space Reserve option is set to "Enable"?

  • A. The volume grows by 100 GB to handle the LUN size of 100 GB.
  • B. The LUN does not use any space from the volume since it is thin provisioned.
  • C. The volume shows that 100 GB has been allocated to the LUN.
  • D. The volume shrinks by 100 GB to provide the LUN 100 GB of space to use.

正解:C


質問 # 66
You are asked to create a data LIF to allow object storage access to a bucket that is hosted in ON TAP software. In this scenario, which service is required for the LIFs service data policy?

  • A. management-BGP
  • B. cluster-core
  • C. data-S3-server
  • D. management-HTTPS

正解:C

解説:
In this scenario, the data LIFs must be configured with a service data policy that includes the S3 server protocol in order to allow object storage access.


質問 # 67
......

NS0-162試験問題と有効なNS0-162問題集PDF:https://jp.fast2test.com/NS0-162-premium-file.html

NS0-162ブレーン問題集学習ガイドにはヒントとコツで試験合格を目指そう:https://drive.google.com/open?id=1RUDk6TflRENtanfFcOvqN_ibR2aCf-3Q


弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

我々の働いている時間: ( GMT 0:00-15:00 )
月曜日から土曜日まで

サポート: 現在連絡 

English Deutsch 繁体中文 한국어