質問 # 12
Click the Exhibit button.
A customer has zoned switches to a host, but the host cannot see the LUNs.
Referring to the exhibit, what needs to be done to make the LUNs visible to the host?
- A. The customer should remove the switches and directly connect the host to the controller ports.
- B. Ports on tme-a700 nodes 1 and 2 should have the fc_nvme protocol removed.
- C. Zoning should be changed to use the 20:06:d0:39:ea:05:03:a3 and 20:08:d0:39:ea:05:03:a3 WWPNs.
- D. Zoning should be changed to use the 50:0a:09:81:80:d2:c3:b8 and 50:0a:09:81:42:c2:b9 WWPNs.
正解:C
質問 # 13
You want to enable the Internal ONTAP engine that quickly Identifies the file and directory differences between two Snapshot copies. In this scenario, which feature would accomplish this task?
- A. SnapDIff
- B. SnapCenter
- C. SnapVault
- D. SnapLock
正解:B
質問 # 14
A node fails on an HA configuration. A successful failover occurs, but your clients that are using the SMB protocol complain that they are not able to access their data.
In this scenario, what caused the problem?
- A. The quota for the qtree has been reached.
- B. One of the cluster Interconnect ports on the surviving node failed.
- C. The surviving node is not licensed for CIFS.
- D. The disk ownership did not transfer correctly.
正解:C
質問 # 15
Which configuration Is supported using NetApp's All SAN Array (ASA)?
- A. single node cluster
- B. 24-node cluster
- C. 12-node cluster
- D. 2-node cluster
正解:B
質問 # 16
A customer wants to migrate a series of LUNs from a third-party array to a FAS. In this scenario, which two tools would the customer use? (Choose two.)
- A. FLI
- B. ADP
- C. NKS
- D. XCP
正解:A、D
解説:
Migrate a series of LUNs from a third-party array to a FAS.
質問 # 17
Exhibit.
You recently added a new ESXi host to your VMware vSphere cluster. However, you cannot mount any of the existing NFS datastores to the host. Referring to the exhibit, which action solves the problem?
- A. Add NFSv4 to the access protocols.
- B. Add HOST 3's IP address to the NFS export policy.
- C. Add SMB/CIFS to the access protocols.
- D. Enable Kerberos in the export policy.
正解:B
質問 # 18
Which type of SVM presents a cluster as a single manageable entity?
- A. cluster SVM
- B. admin SVM
- C. node SVM
- D. system SVM
正解:B
質問 # 19
Which two statements are true about NVMe? (Choose two.)
- A. NQNs are added to subsystems.
- B. Namespaces are mapped to subsystems.
- C. LUNs are mapped to Initiator groups.
- D. NQNs are added to namespaces.
正解:A、B
質問 # 20
Exhibit.
You have a NetApp AFF A400 HA pair with Fabric Pool enabled on all data using the snapshot-only policy. Users are reporting slow restores when they recover files with the Windows Previous Versions tab.
Referring to the exhibit, what is the highest latency seen on restore?
- A. 0
- B. 1
- C. 2
- D. 3
正解:B
質問 # 21
Your company requires WORM archiving of data on their ONTAP cluster. The data must not be able to be deleted even by an administrator. Which ONTAP feature fulfills this requirement?
- A. SnapVault software
- B. SnapMlrror software
- C. SnapLock Compliance
- D. SnapLock Enterprise
正解:A
質問 # 22
A customer wants to migrate a series of LUNs from a third-party array to a FAS. In this scenario, which two tools would the customer use? (Choose two.)
- A. FLI
- B. XCP
- C. ADP
- D. NKS
正解:C、D
質問 # 23
Which security method would be used to authenticate targets and Initiators In an ISCSI environment?
- A. LDAP
- B. CHAP
- C. NIS
- D. /etc/hosts
正解:D
質問 # 24
At which level is inline data compaction applied on an ONTAP AFF system?
- A. aggregate
- B. node
- C. volume
- D. SVM
正解:C
質問 # 25
What are the two capabilities of an SVM administrator? (Choose two.)
- A. to create LUNs
- B. to create new users
- C. to delete snapshot copies
- D. to delegate an aggregate to the SVM
正解:A、C
質問 # 26
Click the Exhibit button.
Your ONTAP 9.7 cluster failed a security audit on the management control plane. Your network security team asked you to allow only cluster1 and SVM1 management on the 192.168.1.0/24 subnet.
In this scenario, where do you apply the default-management service policy shown in the exhibit?
- A. firewall
- B. DNS
- C. port
- D. LIF
正解:D
質問 # 27
Click the Exhibit button.
Only the hosts that are on the 10.1.100.0/24 network can access CIFS shares on SVM lab-fs1.
Referring to the exhibit, what would you do to allow hosts on other networks to access lab-fs1?
- A. Decrease the metric of the route with gateway 10.1.100.1.
- B. Delete the route with gateway 192.168.106.1.
- C. Create a SVM default route for 10.1.100.1.
- D. Increase the metric of the route with gateway 10.1.100.1.
正解:C
質問 # 28
You have two ONTAP clusters and are setting up a new SnapMirror SVM replication (SVM DR) relationship. Which two statements are true in this scenario? (Choose two.)
- A. The target SVM subtype must be sync-destination.
- B. The source SVM subtype must be default.
- C. The target SVM subtype must be dp-destination.
- D. The source SVM subtype must be sync-source.
正解:A、C
質問 # 29
......
NS0-162試験は、90分以内に完了する必要がある60問の多肢選択問題で構成されています。この試験は、NetAppデータストレージと管理に関連するさまざまなトピックをカバーし、ONTAPソフトウェアアーキテクチャ、ストレージプロビジョニング、データ保護、バックアップおよびリカバリ、パフォーマンス最適化、ネットワーキング、セキュリティなどが含まれます。この試験は、候補者のNetAppストレージシステムの構成、モニタリング、トラブルシューティングに関する知識とスキルをテストし、NetApp ONTAPソリューションを管理および管理する能力を包括的に評価します。NS0-162試験に合格することで、候補者のNetAppデータストレージソリューションに関するスキルと知識が認められ、NetAppストレージシステムを管理および管理する専門知識が証明されます。