最新2021年12月27日リアルなNS0-162試験問題集解答で有効なNS0-162問題集PDF
Network Appliance NS0-162試験問題集でPDF問題とテストエンジン
Network Appliance NS0-162 認定試験の出題範囲:
| トピック | 出題範囲 |
|---|---|
| トピック 1 |
|
| トピック 2 |
|
| トピック 3 |
|
| トピック 4 |
|
| トピック 5 |
|
| トピック 6 |
|
| トピック 7 |
|
質問 22
You currently have a Cloud Volumes ONTAP instance running and need to have read/write access to a volume on an on-premises ONTAP cluster.
In this scenario, which feature do you use?
- A. Flash Pool
- B. FlexCache
- C. SnapMirror
- D. Flash Cache
正解: C
質問 23
Click the Exhibit button.
Referring to the exhibit, which volume has a snap reserve value set to zero (0)?
- A. netapp_esx_m1
- B. netapp_no1
- C. netapp_lnx_mi
- D. netapp_esx
正解: C
質問 24
When you perform an upgrade using ONTAP System Manager 9.8, which two statements are true? (Choose two.)
- A. The Images must be manually uploaded to the cluster by using the ONTAP System Manager interface.
- B. The images will be automatically uploaded to the cluster by using the ONTAP System Manager interface from the NetApp Support site.
- C. The update history is available within the ONTAP System Manager interface.
- D. The latest available Images will appear In the ONTAP System Manager interface.
正解: A,C
質問 25
Exhibit.
Miss-----------------
The availability of the remote cluster in the peering relationship shows "Partial." Referring to the exhibit, what is the reason for this status message?
- A. The remote cluster does not have its cluster license applied properly.
- B. Some nodes In the local cluster are not able to contact some or all nodes in the remote cluster.
- C. The Intercluster LIFs on the local cluster are unavailable and not able to communicate to the remote cluster.
- D. The local cluster is unable to authenticate successfully to the remote cluster.
正解: A
質問 26
Which SVM subtype is used by an SVM-DR target?
- A. dp-destination
- B. data
- C. sync-source
- D. default
正解: A
質問 27
A user wants existing data in a FlexVol created in ONTAP 9.1 to be placed into a FlexGroup volume with ONTAP 9.8. In this scenario, which two statements are true? (Choose two.)
- A. You can convert the FlexVol volume to a FlexGroup volume.
- B. Use XCP to copy data from a FlexVol to a FlexGroup.
- C. A FlexVol to FlexGroup conversion is not supported.
- D. Use SnapMirror to replicate data from FlexVol to FlexGroup.
正解: A,D
質問 28
You are currently using SnapMlrror Synchronous (SM-S) to protect a critical workload at your organization and you want to convert the SnapMlrror policy from Sync to StrictSync.
In this scenario, which procedure allows you to achieve this task?
- A. Modify the existing SnapMirror relationship specifying the strictsync policy, then promote It.
- B. Recreate the SnapMirror relationship, specifying the strictsync policy, then re-synchronize it.
- C. Recreate the SnapMlrror relationship, specifying the strictsync policy, then promote It.
- D. Modify the existing SnapMirror relationship specifying the strictsync policy, then re-synchronize It.
正解: C
質問 29
After creating several volumes, you notice that the hosting aggregates Immediately show a decrease In available space. Which volume setting would prevent this outcome?
- A. space guarantee set to "none"
- B. space guarantee set to "volume"
- C. space SLO set to "thick"
- D. space SLO set to "semi-thick"
正解: D
質問 30
All SMB users are reporting that their network share performance Is slow on a new NetApp FAS500f HA pair. You determine that the users have converged network adapters (CNAs) with flow control enabled and no option to disable.
In this scenario, which two flow control settings are recommended on the NetApp ONTAP physical ports? (Choose two.)
- A. Enable flow control end-to-end on data network ports.
- B. Disable flow control end-to-end on cluster network ports.
- C. Disable flow control end-to-end on data network ports.
- D. Enable flow control end-to-end on cluster network ports.
正解: A,B
解説:
https://kb.netapp.com/Advice_and_Troubleshooting/Data_Storage_Software/ONTAP_OS/What_are_the_flow_control_best_practices_for_Ethernet%3F#Clustered_Data_ONTAP_.2F_ONTAP_9_Flow_control_recommendations:
Disable flow control on cluster network ports in the Data ONTAP cluster. Flowcontrol on the remaining network ports (the ports that provide data, management, and intercluster connectivity) should be configured to match the settings within the rest of your environment.
質問 31
You are asked to deploy a 2-node ONTAP Select cluster. The physical hardware Is located In two different locations and you want the aggregates mirrored synchronously between the two data centers. You must ensure high availability and automated switchover.
In this scenario, which two steps would you take to fulfill this requirement? (Choose two.)
- A. Use ONTAP Select Deploy to Install the nodes on the physical hardware.
- B. Ensure that the ONTAP Select Deploy VM resides at a third location other than the two data centers.
- C. Install the SnapMirror Sync license on the cluster.
- D. Use ONTAP Mediator service to make sure that you have a quorum for the two nodes.
正解: A,B
質問 32
Exhibit.
A user cannot save a file on an ONTAP SMB share.
Referring to the exhibit, which action allows the user to save the file?
- A. Set the user permission for the share to write.
- B. Allow the file type *, rtf In the CIFS Server fpolicy.
- C. Let the user save the file to a writeable location.
- D. Synchronize the ONTAP Cluster time to the Active Directory time.
正解: C
質問 33
An application owner at your organization requests a solution for zero RTO In the event of a failure In your primary data center, where you are using NetApp ONTAP 9.8 software with ISCSI LUNs. The owner wants to avoid reconfiguring the application.
Which NetApp solution would you propose to fulfill these requirements?
- A. SVM Disaster Recovery (SVM DR)
- B. SnapMirror Synchronous (SMS)
- C. SnapMirror Business Continuity (SM-BC)
- D. SyncMlrror
正解: B
質問 34
You attempt to create an SVM for CIFS access only.
In this scenario, which three actions must be performed to Join the existing Active Directory? (Choose three.)
- A. Create a cluster LIF.
- B. Create a data LIF.
- C. Create NTP entries.
- D. Create export policies.
- E. Create DNS entries.
正解: B,C,E
解説:
Before creating an SMB server in an Active Domain controller, you must ensure that the cluster time and the time on the domain controllers of the domain to which the SMB server will belong matches to within five minutes. https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.pow-cifs-cg%2FGUID-5AE3CADE-5EF1-403B-A664-2DEA9F13B0C8.html
質問 35
You are asked to delete an SVM that was used for CIFS.
Which two steps must be completed prior to completing this task? (Choose two.)
- A. Delete all data volumes in the SVM.
- B. Delete all LIFs from all SVMs.
- C. Delete the CIFS license.
- D. Stop the SVM.
正解: A,D
質問 36
After attempting to perform an ONTAP upgrade. It falls during the pre-check. In this scenario, what would cause this problem?
- A. offline data LIF
- B. offline volume
- C. encrypted volumes
- D. Idle SnapMirrors
正解: D
質問 37
Click the Exhibit button.
You have a new AFF A400 with a switched 10 GbE cluster interconnect.
Referring to the exhibit, which statement is true about utilizing free ports on slot 3 for the data connection?
- A. The ports in slot 3 cannot be used in any scenario.
- B. Free ports can be used as a 10 GbE connection.
- C. Slot 3 is used as the acceleration card and the cluster interconnect.
- D. Ports in slot 3 can be used for 40/100 GbE data connections.
正解: D
質問 38
Click the Exhibit button.
You are unable to mount an NFS volume named vol1.
Referring to the exhibit, what Is the reason for the mount failure?
- A. The vol1 volume is not mounted to the namespace.
- B. The svm_root volume did not have an export policy rule.
- C. The 0.0.0.0/0 client match did not match the subnet of the NFS client.
- D. The vol1 volume did not have an export policy rule.
正解: D
質問 39
A volume Is set to use Adaptive QoS with the default policy.
In this scenario, which change would affect the QoS throughput ceiling?
- A. The volume Is resized.
- B. Disks are added to the volume's aggregate.
- C. Data is added to the volume.
- D. More clients access the volume.
正解: A
解説:
Reference:
https://kb.netapp.com/Advice_and_Troubleshooting/Data_Storage_Software/ONTAP_OS/What_is_Adaptive_QoS_and_how_does_it_work
質問 40
You are asked to deploy a 2-node ONTAP Select cluster. The physical hardware Is located In two different locations and you want the aggregates mirrored synchronously between the two data centers. You must ensure high availability and automated switchover. In this scenario, which two steps would you take to fulfill this requirement? (Choose two.)
- A. Use ONTAP Select Deploy to Install the nodes on the physical hardware.
- B. Ensure that the ONTAP Select Deploy VM resides at a third location other than the two data centers.
- C. Install the SnapMirror Sync license on the cluster.
- D. Use ONTAP Mediator service to make sure that you have a quorum for the two nodes.
正解: B,D
解説:
https://docs.netapp.com/us-en/ontap-select/reference_plan_ots_two_node.html When a cluster consists of two nodes, it is not possible to achieve the quorum required when a node fails or loses communication. To resolve these types of split-brain situations, every instance of the ONTAP Select Deploy utility includes a mediator service. If you have one or more active two-node clusters, the ONTAP Select Deploy virtual machine administering the clusters must be running at all times.
質問 41
Exhibit.
Referring to the exhibit, what would cause a customer to have an Issue with SVM eplc_fcp when mapping a namespace to a host?
- A. NVMe Is not configured for the SVM.
- B. FC switch zoning has not been done correctly.
- C. NVMe is not licensed on the cluster.
- D. FC has not been licensed on the cluster.
正解: A
質問 42
Your company wants to Increase access security In both their NFS and ISCSI environments. Currently ISCSI Is not authenticated and NFS relies only on export policies for security.
Which two enhancements do you use to satisfy this new criteria? (Choose two.)
- A. Enable Kerberos for iSCSI LUN access.
- B. Enable Challenge-Handshake Authentication Protocol (CHAP) for NFS exports.
- C. Enable Challenge-Handshake Authentication Protocol (CHAP) for ISCSI LUN access.
- D. Enable Kerberos for NFS exports.
正解: A,B
質問 43
Which two types of capacity tiers are supported with FabrlcPool aggregates In ONTAP 9.8? (Choose two.)
- A. NFS Export
- B. S3 Object Store
- C. SWIFT Object Store
- D. StorageGRID Object Storage
正解: B,D
質問 44
......
信頼できるNetApp NCDA ONTAP NS0-162問題集PDF2021年12月27日最近更新された問題:https://jp.fast2test.com/NS0-162-premium-file.html
最新NS0-162試験問題集には合格保証付きます:https://drive.google.com/open?id=1RUDk6TflRENtanfFcOvqN_ibR2aCf-3Q