質問 # 187
What is the remote management option for G Series VxRail nodes?
- A. iDRAC
- B. IPMI/BMC
- C. RMM
- D. iLO
正解:B
質問 # 188
Which VxRail configurations can be reviewed using the As-Built Configuration Report at the time the report is generated?
- A. Node PSNT numbers, license activation dates, and Private Management Network VLAN ID
- B. Node names, vSAN interface IP addresses, and VxRail Manager users and passwords
- C. Node models, license keys, vSAN VLAN ID, and vMotion VLAN ID
- D. vMotion interface IP addresses, vCenter users and passwords, and opened firewall ports
正解:C
質問 # 189
During the activation of Internal SRS, the implementation engineer receives a message that the deployment has failed What is a possible cause?
- A. Witness Gateway not configured following Dell best practices
- B. VxRail status already set to installed' in IB database
- C. SRS VE Gateway on the same subnet as the VxRail Manager
- D. Site ID mismatch between the IB database and the SRS Wizard
正解:D
質問 # 190
After the installation of a VxRail cluster, the vSAN Health Check shows a hardware compatibility warning.
Where can detailed information about this health check and its resolution be found?
- A. vCenter Server Help
- B. Dell EMC Knowledge Base
- C. VMware Knowledge Base
- D. VxRail Manager Help
正解:C
質問 # 191
Match the management tool that is used to perform the associated operation in a VxRail environment.
正解:
解説:
質問 # 192
What is a valid 2-node VxRail cluster configuration?
- A. 2x 1 GbE and 2x 10 GbE in a switch configuration and internal vCenter
- B. 2x 1 GbE and 2x 10 GbE in a direct-connect configuration and external vCenter
- C. 2x 10 GbE and 2x 25 GbE in a direct-connect configuration and internal vCenter
- D. 2x 10 GbE and 2x 25 GbE in a switch configuration and external vCenter
正解:B
質問 # 193
What is a consideration when using ToR switches with VxRail?
- A. VxRail iDRAC Management ports require 10 GbE ports.
- B. IPv6 Multicast must be disabled in this environment.
- C. All-Flash models must use 10 GbE or faster ports.
- D. Link aggregation must be enabled on VxRail switch ports.
正解:C
質問 # 194
A 4-node VxRail Model E560F solution with an embedded vCenter and Log Insight is planned for deployment.
Prior to deployment, DNS records must be created for which hosts?
- A. vCenter Server, ESXi hosts, VxRail Manager, and Log Insight
- B. DNS records are automatically created during VxRail deployment
- C. vCenter Server, first ESXi host, VxRail Manager, and iDRAC
- D. vCenter Server, ESXi hosts, VxRail Manager, and iDRAC
正解:A
質問 # 195
A VxRail E560F model was delivered six months ago and is now scheduled to be installed with the target code.
What is the correct order of steps to complete this task?
正解:
解説:
質問 # 196
In addition to hardware monitoring, what is the purpose of the Dell PTAgent service on a VxRail node?
- A. Hardware discovery and firmware installation
- B. VxRail node discovery and software upgrades
- C. Hardware discovery and VxRail VIB installation
- D. BOSS upgrade and firmware installation
正解:A
質問 # 197
An implementation engineer is deploying a new VxRail cluster.
What should they confirm before installing the hardware?
- A. At least 24 in (61 cm) of clearance must exist in front of and behind the cabinet
- B. Service laptop is on the same IP network as the iDRACs
- C. Power distribution supports only the power rating of a single node
- D. Redundant power zones exist with adequate power cables
正解:A
質問 # 198
Match each VxRail data protection solution with its functionality.
正解:
解説:
1 - C
2 - A
3 - D
4 - B
質問 # 199
A VxRail cluster is being deployed with the VxRail Deployment Wizard.
For which IP addresses must FQDNs be resolved by DNS?
- A. Only the first VxRail ESXi node, vCenter Server, and VxRail Manager VM
- B. All VxRail ESXi nodes, vRealize Operation Manager, and VxRail Manager VM
- C. vCenter Server and VxRail Manager VM only
- D. All VxRail ESXi nodes, vCenter Server, and VxRail Manager VM
正解:D
質問 # 200
What is the basis used for VMware vSAN licensing?
- A. TB capacity per node
- B. TB capacity per cluster
- C. Per CPU socket
- D. Per disk group
正解:C
質問 # 201
What data protection option is included with VxRail?
- A. RecoverPoint for VM vSphere Replication
- B. PowerProtect Software Data Domain Cloud Tier
- C. RecoverPoint for VM Avamar
- D. vSphere Replication NetWorker
正解:A
質問 # 202
A VxRail cluster 4.7.xxx environment is managed by the internal vCenter Server. An implementation engineer plans to deploy a new VxRail cluster using the existing vCenter Server instance, then use the customer-supplied VDS to manage both VxRail clusters.
What must be done?
- A. Upgrade the VxRail version from 4.7.xxx to 7.0.000
- B. Upgrade the internal vCenter Server to version 7.0
- C. Migrate the internal vCenter Server to an external vCenter Server, then upgrade the VxRail 4.7.xxx to 7.0.100
- D. Migrate the internal vCenter Server to an external vCenter Server, then merge the PSC
正解:C
質問 # 203
A system administrator wants to collect a generated log file via the VxRail REST API.
Which command should they use?
- A. GET /v1/support/logs/<Log_ID>/download
- B. GET /v1/support/logs/<Log_ID>
- C. POST /v1/support/logs/<Log_ID>/download
- D. POST /v1/support/logs/
正解:A
質問 # 204
A systems engineer needs to ensure that the VxRail system is healthy and any issues found are addressed prior to starting an upgrade process.
Where in the vSphere Client can they review alarms and overall vSAN health?
- A. Triggered Alarms > Issues and Alarms > All issues
Triggered Alarams > vSAN > Skyline Health - B. Monitor > Issues and Alarms > All issues
Monitor > vSAN > Skyline Health - C. Triggered Alarms > All Issues > Issues and Alarms
Triggered Alarms > vSAN > Health - D. Monitor > All Issues > Issues and Alarms
Monitor > vSAN > Health
正解:B
質問 # 205
When using the RASR method to reset a VxRail node, which boot device is selected?
- A. IDSDM
- B. RASRUSB
- C. SATADOM
- D. IDRAC SD CARD
正解:A
質問 # 206
Which series of VxRail nodes supports either Intel or AMD processors and either hybrid or All-Flash storage?
- A. E Series
- B. D Series
- C. V Series
- D. G Series
正解:A
質問 # 207
......
無料でゲット!2024年最新のに更新されたEMC D-VXR-DY-23試験問題と解答:https://jp.fast2test.com/D-VXR-DY-23-premium-file.html
合格させるD-VXR-DY-23試験には更新された345問題あります:https://drive.google.com/open?id=1r07SaJqHmYKSzPNoxCQh3A_HHe_X_9Xv