2025年最新のCFPE問題集PDFでCFPEリアル試験問題解答 [Q50-Q72]

Share

2025年最新のCFPE問題集PDFでCFPEリアル試験問題解答

有効なCFPEテスト解答とNFPA CFPE試験PDF問題を試そう


NFPA CFPE 認定試験の出題範囲:

トピック出題範囲
トピック 1
  • Administrative: This topic tests fire protection engineers and planners on their ability to prepare clear and concise reports based on observations from plan reviews. Engineers must ensure that findings align with applicable codes, standards, and jurisdiction policies while resolving deficiencies and processing documents following established procedures.
トピック 2
  • Site Plan Review: In this topic, fire protection engineers must demonstrate their ability to evaluate plans for fire flow, hydrant locations, and spacing to ensure compliance with codes and standards. Engineers will also be tested on evaluating emergency vehicle access, identifying deficiencies, and documenting them per jurisdictional policies.
トピック 3
  • Fire Protection and Life Safety Systems Review: This topic assesses fire protection engineers' ability to identify and evaluate the requirements for fire protection and life safety systems in plans. Engineers must demonstrate how to review the installation of fire protection systems, including pre-engineered systems, and ensure compliance with standards while documenting deficiencies as required by jurisdictional policies.
トピック 4
  • Building Plan Review: Fire protection engineers will need to verify occupancy classifications, construction types, and occupant loads in building plans. The exam tests engineers’ ability to ensure these elements comply with applicable codes and standards, as well as their ability to document and report deficiencies according to jurisdictional procedures.
トピック 5
  • General Knowledge: This topic assesses fire protection engineers' knowledge of relevant codes and standards and their ability to determine the correct document, edition, and topic for a fire protection issue. It also evaluates the engineers' participation in legal proceedings, ensuring accurate testimony and appropriate conduct during proceedings.

 

質問 # 50
What is the maximum heat release rate of a single fuel package containing foamed plastics that is part of an exhibit booth'?

  • A. 75 kW
  • B. 50 kW
  • C. 150 kW
  • D. 100 kW

正解:D

解説:
According to NFPA 1031, which covers the qualifications for professionals in fire safety and code compliance, specific requirements exist for fire protection systems, including materials used in exhibit booths.
In situations where foamed plastics are part of an exhibit booth's construction, the maximum allowable heat release rate of a single fuel package is 100 kW.
This value aligns with the guidance provided to ensure that exhibit booths constructed with foamed plastics do not exceed safe fire load limits, thereby reducing the risk of fire propagation in exhibition settings. By maintaining the heat release rate at or below 100 kW, fire protection professionals can manage fire hazards effectively, ensuring compliance with safety regulations as outlined in NFPA 1031.
No exact references to the NFPA 1031 standard were found in the provided documents. This information, however, is consistent with general fire protection principles concerning maximum heat release rates in fire prevention codes.
For exact chapter and section references, a direct examination of the most current NFPA 1031 standard should be conducted.


質問 # 51
Exhibit.


Based on the figure, what is the total width of exiting required?

  • A. 7,750 m (196 800 mm)
  • B. 3,100 in (78.740 mm)
  • C. 4,650 in (118100 mm)
  • D. 6,200 in (157 500 mm)

正解:D

解説:
The total width of exits required is determined by calculating the number of occupants and applying the required exit width per occupant based on the applicable building or fire code (such as NFPA 101, Life Safety Code). For a large assembly occupancy such as a soccer field with 15,500 people, the exit width would be calculated using a standard factor (usually in inches or millimeters per person) to ensure that all occupants can evacuate safely in an emergency. Based on standard exit width factors and the number of people, the correct total exit width required is approximately6,200 inches (157,500 mm).


質問 # 52
What occupancy classification is a community college classroom with an occupant load of 40 persons or less?

  • A. Institutional
  • B. Educational
  • C. Assembly
  • D. Business

正解:D

解説:
A community college classroom with an occupant load of 40 persons or less is classified as a "Business" occupancy according to NFPA 101, Life Safety Code. This classification applies to educational occupancies above the 12th grade with fewer than 50 persons. Classrooms and offices in such settings are considered business occupancies, and this classification dictates the specific fire safety requirements, including egress and fire protection features.
Top of Form
Bottom of Form


質問 # 53
Exhibit.

What is the construction type specified for the new addition for plan set Tl?

  • A. Type (211)
  • B. Type II (111
  • C. Type II (000)
  • D. Type III (200)

正解:C

解説:
The construction type specified for the new addition in plan set T1 isType II (000). This construction type, as defined in the International Building Code (IBC), refers to buildings with non-combustible materials for all structural elements, but with no fire-resistance rating requirements for any of the structural components. This is typical for newer additions where fire safety is achieved through non-combustible materials and other fire protection systems, such as sprinklers.
Top of Form
Bottom of Form


質問 # 54
New manual fire alarm boxes must be within what distance from the door?

  • A. 34 in (2,133 mm)
  • B. 72 in (1,829 mm)
  • C. 96 in (2,438 mm)
  • D. 60 in (1,524 mm)

正解:D

解説:
New manual fire alarm boxes must be installed within 60 inches (1,524 mm) from the door, according to NFPA 72, National Fire Alarm and Signaling Code. This placement ensures that the alarm is easily accessible and visible for occupants as they exit, facilitating prompt alarm activation in case of fire or emergency.
Top of Form
Bottom of Form


質問 # 55
Records related to fire plan review are considered to be

  • A. unnecessary to maintain
  • B. privileged information
  • C. strictly confidential
  • D. public domain documents

正解:D

解説:
Records related to fire plan reviews are generally considered public domain documents. They are typically part of the public record, especially after a project has been completed, to ensure transparency, accountability, and public safety. However, access may be subject to local laws and regulations governing public records.
Top of Form
Bottom of Form


質問 # 56
What is the maximum spacing for standard pendent sprinklers for light hazard occupancies that are hydraulically calculated?

  • A. 15 ft (4.6 m)
  • B. 18 ft (5.5 m)
  • C. 10 ft (3.05 m)
  • D. 12 ft (3.7 m)

正解:A

解説:
The maximum spacing for standard pendent sprinklers in light hazard occupancies that are hydraulically calculated is 15 feet (4.6 meters). This spacing complies with NFPA 13, which provides the design requirements for sprinkler systems, ensuring adequate coverage and water distribution to control or extinguish a fire in light hazard areas.


質問 # 57
What percentage of wall area may be covered with art work in a sprinklered educational occupancy?

  • A. 50%
  • B. 20%
  • C. 10%
  • D. 15%

正解:B

解説:
According to NFPA 101, Life Safety Code, in a sprinklered educational occupancy, no more than 20% of the wall area may be covered with artwork or teaching materials to minimize fire hazards and ensure safe evacuation routes (NFPA 101, Section 14.7.4). This percentage is intended to balance educational needs with fire safety requirements.
Top of Form
Bottom of Form


質問 # 58
The tops of wall mounted audible fire alarm notification appliances shall be a minimum of what height above the finished floor'?

  • A. 88 in (2.23 m)
  • B. 90 in.(2.29 m)
  • C. 80 in. (2.03 m)
  • D. 96 in (2.43 m)

正解:C

解説:
According to NFPA 72, National Fire Alarm and Signaling Code, the tops of wall-mounted audible fire alarm notification appliances should be mounted at a minimum height of 80 inches (2.03 meters) above the finished floor. This height ensures that the devices are installed at an optimal position for sound propagation while remaining accessible for maintenance and testing.
Top of Form
Bottom of Form


質問 # 59
The symbol above is a representation of which one of the following?

  • A. Riser
  • B. Utility meter
  • C. Fire hydrant
  • D. Floor dram

正解:C

解説:
In the context of NFPA standards, particularly NFPA 1031, "Standard for Professional Qualifications for Fire Inspector and Plan Examiner," the symbol that represents a "Fire hydrant" is universally recognized in fire protection systems. NFPA 1031 outlines various competencies and knowledge areas required for fire inspectors and plan examiners, including understanding symbols and terminology related to fire protection systems.
Reference from NFPA 1031: NFPA 1031 emphasizes that fire inspectors and plan examiners must be familiar with different components of fire protection systems, which includes being able to identify symbols used in construction and fire safety plans. Symbols such as those representing fire hydrants, risers, floor drains, and utility meters are part of the essential knowledge for professionals in this field to ensure compliance with fire codes and standards during plan reviews (NFPA 1031, Section 4.2.1 - Understanding of fire protection systems and their components).
Understanding and correctly identifying these symbols is crucial for maintaining effective fire safety and ensuring the correct placement and functioning of fire protection equipment. The fire hydrant symbol, in particular, is a key element in fire protection drawings and plans, indicating the location of hydrants that provide water supply to firefighters in the event of a fire.


質問 # 60
In positive alarm sequence systems trained personnel shall have a maximum of how many seconds during the alarm investigation phase to evaluate the fire condition and reset the system'?

  • A. 180 seconds
  • B. 60 seconds
  • C. 90 seconds
  • D. 120 seconds

正解:D

解説:
According to NFPA 72, National Fire Alarm and Signaling Code, in positive alarm sequence systems, trained personnel have a maximum of 120 seconds (2 minutes) during the alarm investigation phase to evaluate the fire condition and reset the system. This time frame is provided to allow personnel to assess whether the alarm is legitimate or false before activating a full evacuation or emergency response.
Top of Form
Bottom of Form


質問 # 61
For the purposes of fire sprinkler protection, occupancies where combustibility is low. quantity of combustibles is moderate, and stockpiles of combustibles do not exceed 8 ft (2.4 m). are called

  • A. Ordinary hazard (Group 2)
  • B. Light hazard
  • C. Extra hazard (Group 1)
  • D. Ordinary hazard (Group 1)

正解:D

解説:
Occupancies where the combustibility is low, the quantity of combustibles is moderate, and stockpiles of combustibles do not exceed 8 feet (2.4 meters) are classified as "Ordinary hazard (Group 1)." This classification, as defined in NFPA 13, Standard for the Installation of Sprinkler Systems, is used to determine the design density and spacing of sprinklers required to provide adequate fire protection.


質問 # 62
Exhibit.

On plan C1 what is the widthof the fire department access driveway on the south facing side of the building wing closes! lo Bedford Street?

  • A. 18 ft (5.5 m)
  • B. 20 ft (6.1 m)
  • C. 24 ft (7.3 m)
  • D. 16 ft (4.9 m)

正解:A


質問 # 63
The responsibility to promulgate rules that cover plan review is established by

  • A. NFPA 101.
  • B. NFPA 220.
  • C. NFPA 1.
  • D. NFPA 170.

正解:C

解説:
The responsibility to promulgate rules covering plan review is established by NFPA 1, Fire Code. NFPA 1 provides guidelines and regulations for the enforcement of fire safety codes, including requirements for plan reviews, inspections, and other fire prevention measures. It is the overarching code that jurisdictions often adopt to ensure uniform fire safety standards.


質問 # 64
Which one of the following is an architectural drawing that shows the vertical view of a building, including floors, building height, and the grade of surrounding ground?

  • A. Detailed view
  • B. Elevation view
  • C. Plan view
  • D. Sectional view

正解:B

解説:
An elevation view is an architectural drawing that shows the vertical view of a building, including floors, building height, and the grade of surrounding ground. It is used to depict the exterior or interior walls of a structure from a vertical perspective. This view provides details on the heights of various building elements and their relationships to the surrounding terrain.


質問 # 65
If a sprinkler system is supplied with water from a gravity tank, the gravity tank shall be installed in accordance with what standard in order to be acceptable as a source of water?

  • A. NFPA13
  • B. NFPA22
  • C. NFPA24
  • D. NFPA20

正解:B

解説:
If a sprinkler system is supplied with water from a gravity tank, the tank must be installed in accordance with NFPA 22, Standard for Water Tanks for Private Fire Protection. NFPA 22 provides the requirements for the design, construction, installation, and maintenance of water tanks used for fire protection. It ensures that the gravity tank meets the necessary standards to be a reliable and effective water source for the sprinkler system.
Top of Form
Bottom of Form


質問 # 66
What is the minimum required rating for a fire door assembly installed in a 2-hour rated fire barrier?

  • A. 45 minutes
  • B. 2-hours
  • C. 1-1/2 hours
  • D. 1-hour

正解:C

解説:
The minimum required rating for a fire door assembly installed in a 2-hour rated fire barrier is 1-1/2 hours.
According to NFPA 80, Standard for Fire Doors and Other Opening Protectives, fire door assemblies are typically rated at three-quarters of the rating of the wall in which they are installed. Thus, a 2-hour rated wall requires a 1-1/2-hour fire door assembly.


質問 # 67
Exhibit.

In the figure what would be the minimum diagonal distance between stairways 1 and 2?

  • A. 22 ft 4 in (6.8 m)
  • B. 43 ft 9 in (13.3 m)
  • C. 37 ft 3 in. (11.3m)
  • D. 29 ft 2 in (8.9 m)

正解:C

解説:
To determine the minimum diagonal distance between stairways 1 and 2, we need to calculate the diagonal length of the path between points A and H on the provided floor plan. According to NFPA 1031, Plan Examiners must verify egress routes to ensure compliance with NFPA standards, particularly regarding the minimum distance between exits to ensure that a fire in one location does not cut off access to an alternative exit.
Using the Pythagorean theorem for diagonal distance in a rectangular area, the calculation between stairways A (Stairway 1) and H (Stairway 2) is as follows:
Distance=(Length2+Width2)\text{Distance} = \sqrt{(Length^2 + Width^2)}Distance=(Length2+Width2) Based on the floor plan's measurements, the approximate diagonal distance between stairways is 37 ft 3 in (11.3 m). Therefore, option C is the correct answer.


質問 # 68
Exhibit.

The automatic fire sprinkler system remote area located on planF2.0 indicates that the fire sprinkler system has been designed to deliver

  • A. 15 gpm ( 57 L/min) over 1 500 ft2 (139 m2)
  • B. 20 gpm ( 76 L/mm) over 2 000 tt2 (186 m2)
  • C. 20 gpm ( 76 L/min) over 1 500 ft2 (139 m2)
  • D. 10 gpm ( 38 L/min) over 1 500 tt2 (139 m2)

正解:B

解説:
In sprinkler design, the "remote area" refers to the section of a building that is most challenging to protect with sprinklers due to its location and characteristics. The design criteria usually specify the minimum density of water (gallons per minute per square foot or liters per minute per square meter) over a specified area that the system must deliver. Based on the standard requirements for typical commercial occupancies, a delivery rate of15 gpm (57 L/min) over 1,500 ft² (139 m²)is common for light to ordinary hazard classifications.
Top of Form
Bottom of Form


質問 # 69
What is the permitted fire flow reduction for two buildings on the same lot with a separation of 40 ft (12 m)?

  • A. 33 percent
  • B. 50 percent
  • C. 25 percent
  • D. 40 percent

正解:C

解説:
For two buildings on the same lot with a separation of 40 ft (12 m), a fire flow reduction of 25 percent is permitted. This reduction is typically allowed under the guidelines of NFPA standards or local fire codes, which consider the distance between structures and the associated fire risk. A separation of 40 feet is sufficient to warrant a 25 percent reduction in required fire flow, assuming that other fire safety measures, such as sprinkler systems, are in place.


質問 # 70
The symbol above is a representation of which one of the following?

  • A. Reducer
  • B. Riser
  • C. Check valve
  • D. Post-indicator valve

正解:C

解説:
The symbol in question represents a check valve. A check valve is used in a fire protection system to prevent the backflow of water, ensuring that water flows in only one direction through the pipes. Symbols for fire protection components like check valves are standardized in NFPA codes and are critical for understanding the layout and functionality of fire suppression systems.


質問 # 71
Exhibit.

What is the occupant load of the stage on plan A5?

  • A. 58 people
  • B. 60 people
  • C. 62 people
  • D. 56 people

正解:A