
[2024年更新]無料Hybrid-Cloud-Observability-Network-Monitoring試験問題集はパス試験は超簡単
Hybrid-Cloud-Observability-Network-Monitoring試験問題集でHybrid-Cloud-Observability-Network-Monitoring練習テスト問題
質問 # 65
Which two of the following tasks must be accomplished to monitor servers and connections in a load-balancing environment? (Choose two.)
- A. enable F5 iControl polling
- B. enable CLI polling
- C. add Cisco Nexus device in network device configuration manager
- D. add Cisco Nexus device in network health / performance monitoring
正解:A、D
質問 # 66
Which two of the following effects would apply to a situation where a NetPath probe polling interval is increased to 15 minutes from the default value of 10 minutes? (Choose two.)
- A. probe is more likely to show all routes
- B. accuracy is decreased
- C. probe will not complete successfully
- D. accuracy is increased
正解:A、B
質問 # 67
After creating a new device studio poller that appears to be returning values on a test device, it is then applied to additional nodes. One of these new devices is not returning the statistics of the test node. Which two of the following reasons might be the cause of the issue? (Choose two.)
- A. new device needs to be rebooted
- B. object IDs (QIDs) are not supported
- C. communication issue exists in new device
- D. devices have different firmware versions
正解:B、D
質問 # 68
How are additional collection ports added?
- A. separate listed ports with a comma in the NetFlowcollector services widget
- B. replace existingport with new port in theNetFlow collector services widget
- C. stop SolarWinds' NetFlow service and separate listed ports with a comma in theNetFlow collector services widget
- D. stop SolarWinds' NetFlow service and change the collection port in the NetFlow collector services widget
正解:A
質問 # 69
Which two of the following technologies are used when building device studio pollers? (Choose two.)
- A. power supply status for vital statistics view
- B. CPU and memory load of single processor
- C. VLAN and VRF on a dedicated widget
- D. machine type for node details widget
正解:A、D
質問 # 70
Which option is available when choosing the collect Windows events without an agent so that Windows event logs can be recognized?
- A. Convert Windows events to log files with SolarWinds event log forwarder.
- B. Convert Windows events to svslog with SolarWinds event log forwarder.
- C. Convert Windows events to VMware with SolarWinds event log forwarder.
- D. Convert Windows events to traps with SolarWinds event log forwarder.
正解:B
質問 # 71
How is HA mode monitored and configured for site-to-site VPN tunnels within a Cisco ASA firewall?
- A. WMI > ICMP > CLI Polling
- B. SNMP > CLI Polling
- C. Agent > CLI Polling
- D. SNMP > ICMP > CLI Polling
正解:B
質問 # 72
Which NetFlow component can be applied to an interface to track IPv4 traffic?
- A. flow exporter
- B. flow record
- C. flow monitor
- D. Iflow sampler
正解:C
質問 # 73
Which custom poller supports multiple object IDs (OIDs)?
- A. device studio
- B. universal device poller (UDP)
- C. component monitor
- D. hardware health
正解:B
質問 # 74
SNMP get type defines the SNMP polling method used by a universal device poller (UDP) to get the device's object ID (OID) values.
Which SNMP get type retrieves values from a particular column?
- A. column
- B. next
- C. data
- D. table
正解:D
質問 # 75
Which two of the following points can be checked when the node status is "unknown"? (Choose two.)
- A. polling method
- B. ping response
- C. view method
- D. OID
正解:A、B
質問 # 76
Which two of the following components are required to successfully create a NetPath probe? (Choose two.)
- A. source IP address
- B. Linux agent
- C. Windows agent
- D. connection port
正解:C、D
質問 # 77
It is taking longer than normal for a single mission critical node to poll for data. Where would the polling interval for the node be changed?
- A. Node Details Summary > Edit Node > Polling
- B. Settings > All Settings > Polling Settings
- C. Settings > All Setting > Core Thresholds
- D. Node Details Summary > Resources > Memory
正解:A
質問 # 78
Event logs are to be collected from Windows servers in order to be analyzed in hybrid cloud observability.
Which two of the following actions must be taken in order to accomplish this ask? (Choose two.)
- A. deploy and configure the platform agent to collect the logs
- B. configure a rule on hybrid cloud observability to poll the server and collect logs
- C. configure a rule on hybrid cloud observability to read event log folder locations
- D. configure server to send logs to another server running the platform
正解:A、D
質問 # 79
What is required to submit an MIB database update request to SolarWinds?
- A. type of widget to populate data
- B. polling interval to monitor the metric
- C. specific object ID (QID) for polling
- D. SNMP or MIB walk from the device
正解:D
質問 # 80
A device studio poller is being built for a router statistic. It is determined that its object ID (OID) does not exist in SolarWinds' MIB database. What is the best workaround for this situation?
- A. download database from customer portal
- B. select SNMP and ICMP as the router's polling method
- C. consult vendor and add OID to the database
- D. select manually define object identifier and specify SNMP
正解:D
質問 # 81
A "no data" message is displayed in NetFlow charts. How can this be resolved?
- A. Refresh the current window.
- B. Shorten the time for view and resource.
- C. Confirm account has viewing permissions.
- D. Restart collector service.
正解:C
質問 # 82
In device studio, which three of the following technologies are supported for custom polling? (Choose three.)
- A. interface traffic
- B. single CPU / memory
- C. multi-CPU / memory
- D. node details
正解:B、C、D
質問 # 83
If the data collected for hardware health is incorrect, which step could rectify the issue?
- A. Create a custom goller in device studio for fan speed, power supply, and temperature.
- B. Download the MIB file from the SolarWinds website and add it to the device's firmware.
- C. Change the MIB tree used for polling.
- D. Change the poller assigned to sensor.
正解:C
質問 # 84
Which port needs to be open in order to analyze flow and monitor CBQoS?
- A. Flow (SNMP, 161), CBQoS (UDP, 2055)
- B. Flow (TCP, 2055), CBQoS (SNMP, 161)
- C. Flow (SNMP, 161), CBQoS (TCP, 2055)
- D. Flow (UDP, 2055), CBQoS (SNMP, 161)
正解:D
質問 # 85
The unclassified traffic in the web console has been identified as MSSQL traffic. It is known as an application mapping that hybrid cloud observability maps by default. Which two of the following reasons explain why the traffic is showing as unclassified? (Choose two.)
- A. The source or the destination port field is not present.
- B. A different port is being used.
- C. The version of MSSQL being used is not supported.
- D. A firewall is blocking the traffic.
正解:A、B
質問 # 86
In customizing the flow direction of SolarWinds' platform views, which statement is true?
- A. Both ingress and egress views are available for 24 hours.
- B. Both ingress and egress views are available for 48 hours.
- C. Both ingress and egress views are available for the next two sessions.
- D. Both ingress and egress views are available for the current session only.
正解:D
質問 # 87
An agent is deployed to the Windows server in order to monitor logs, however logs are not coming in from the related agent. It is confirmed that the agent software is deployed and installed on the target machine.
What additional setting needs to be checked?
- A. log forwarding feature is enabled
- B. correct rule to read logs is configured
- C. polling method is set to agent
- D. polling method is set to WMI
正解:B
質問 # 88
A node is not able to calculate CPU load threshold. Where in SolarWinds' platform can a user confirm CPU load is included in the node status calculation?
- A. core thresholds
B custom poller thresholds - B. polling settings
- C. node status contributors
正解:B
質問 # 89
......
Hybrid-Cloud-Observability-Network-Monitoring試験問題集でHybrid-Cloud-Observability-Network-Monitoring練習テスト問題:https://jp.fast2test.com/Hybrid-Cloud-Observability-Network-Monitoring-premium-file.html
無料Hybrid-Cloud-Observability-Network-Monitoring学習問題集ガイド試験問題解答はここ:https://drive.google.com/open?id=1sm4DT_3BoEu7yQGMORF_hV42c62IjY6S