最新DES-1241合格保証試験問題集には正確で最新な問題があります [Q57-Q75]

Share

最新DES-1241合格保証試験問題集には正確で最新な問題があります

DES-1241試験ブレーン問題集で学習注釈と理論


EMC DES-1241は、PowerStoreに特化したプラットフォームエンジニア向けの業界認定試験です。この試験は、PowerStoreストレージシステムをインストール、構成、管理、トラブルシューティングするために必要なスキルと知識をテストするために設計されています。この認定試験は、ストレージ分野でキャリアを向上させたいITプロフェッショナルを対象としています。

 

質問 # 57
Match the correct non-disruptive upgrade process step (answer column) with the correct sub-step (match column).

正解:

解説:


質問 # 58
How many nodes are in the base enclosure?

  • A. 2 nodes configured as Active-Standby
  • B. 1 node with high availability enabled
  • C. 2 nodes configured as Active-Active
  • D. 1 node with duel connectivity

正解:C


質問 # 59
What is the protocol used for the storage network?

  • A. SMB
  • B. iSCSI
  • C. FC
  • D. NFS

正解:B


質問 # 60
What is the alert severity if the license expiration date is within a week?

  • A. Minor
  • B. Warning
  • C. Information
  • D. Major

正解:A


質問 # 61
Refer to the exhibit.

What is the result of the network configuration show for a Dell EMC PowerStore T node A management port?

  • A. VLAN 1 passes tagged traffic, VLAN 1501 passes untagged traffic
  • B. VLAN 1 and VLAN 1501 pass untagged traffic
  • C. VLAN 1 passes untagged traffic, VLAN 1501 passes tagged traffic
  • D. VLAN 1 and VLAN 1501 pass tagged traffic

正解:C


質問 # 62
What describes the power requirements for Dell EMC PowerStore?

  • A. Lower model numbered systems require less AC line current than higher model numbered systems
  • B. T models require less total power than X models
  • C. Lower model numbered systems require less input voltage (VAC) than higher model numbered systems
  • D. X models require less total power than T models

正解:A

解説:
Maximum input power 240 VAC ± 10%, single phase For 100-120V, a customer-supplied step-up transformer is required AC Line Current (operating maximum at 200 VAC) 8.1 A 8.1 A 9.0 A 9.0 A 9.3 A 10.4 A https://www.dell.com/support/manuals/en-us/powerstore-5000/pwrstr-plang/power-requirements-for-powerstore-x-model-and-powerstore-t-model?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us


質問 # 63
What is an alternative way to collect logs instead of using the Dell EMC PowerStore manager GUI?

  • A. USB stick inserted into the system
  • B. Data Collect using Service Container
  • C. Discovery Utility
  • D. Data Collect using vCenter

正解:B


質問 # 64
How many fan module failures can a node tolerate?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:D

解説:
Reference:
https://www.dellemc.com/en-us/collaterals/unauth/white-papers/products/storage/h18149-dell-emc-powerstore-platform-introduction.pdf (14)


質問 # 65
Refer to the exhibit.

A Storage Administrator is troubleshooting a Dell EMC PowerStore T hardware issue. They observe that the base enclosure LED circled is blue. What does this indicate?

  • A. Cluster has only a single appliance
  • B. Base enclosure has a component hardware fault
  • C. Base enclosure hardware is operating normally
  • D. Appliance has a node in service mode

正解:C


質問 # 66
What is the alert severity if the license expiration date is within a week?

  • A. Warning
  • B. Information
  • C. Minor
  • D. Major

正解:A


質問 # 67
What is the result of setting a VLAN ID of 0 on a network when running ICW for Dell EMC PowerStore?

  • A. Default route is set
  • B. Network will pass untagged traffic
  • C. Network will pass tagged traffic
  • D. Static route is set

正解:B


質問 # 68
A Storage Administrator notices a Critical alert present in Dell EMC PowerStore Manager relating to data integrity. What action within the alert details slide-out panel is helpful in troubleshooting the problem?

  • A. Examine Notifications to obtain a list of corrective actions
  • B. Select the Gather Support Materials from Service and Support
  • C. Access the Repair Flow link to schedule a support engagement
  • D. Re-engage support through previous listed Related Events

正解:A


質問 # 69
Which LED combination shows a connected and working node?

  • A. power: LED: steady green fault LED: off
  • B. power LED: blinking green fault LED: off
  • C. power LED: blinking green fault LED: blue
  • D. power LED: steady green fault LED: amber

正解:A


質問 # 70
Which Dell EMC PowerStore network uses an appliance backplane?

  • A. MPIO
  • B. Inter-cluster management
  • C. Inter-node
  • D. ICD

正解:C

解説:
Reference:
https://blocksandfiles.com/2020/05/05/dell-emc-powerstore-midrange-array-launch-analysis/


質問 # 71
Refer to the exhibit.

What Dell EMC PowerStore ToR front-end cabling is shown?

  • A. VLTi interconnectivity
  • B. Management and discovery
  • C. Core switch uplink
  • D. OOB Management

正解:A


質問 # 72
When connecting a PowerStore base enclosure to 2 expansion enclosures, match the base SAS ports in column A to their corresponding expansion LCC ports in column B.

正解:

解説:

Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-1000/pwrstr-isg/cable-the-base-enclosure-to- the-expansion-enclosure?guid=guid-d68d049f-2b77-489f-b1ab-553f4f3de8aa&lang=en-us


質問 # 73
What describes Dell EMC PowerStore heat dissipation?

  • A. Lower model numbered systems have lower heat dissipation specifications than higher model numbered systems
  • B. X systems have higher heat dissipation specifics than T systems
  • C. T systems have higher heat dissipation specifics than X systems
  • D. Higher model numbered systems have lower heat dissipation specifications than lower model numbered systems

正解:B


質問 # 74
What describes Dell EMC PowerStore X power down?

  • A. PowerStore X node, appliance, or cluster power down utilizes the VSi plugin to perform the needed vCenter server operations
  • B. PowerStore X node, appliance, or cluster power down is done entirely with vCenter server commands
  • C. Powering down a PowerStore X node, appliance, or cluster requires additional vCenter server commands
  • D. Powering down a PowerStore X node, appliance, or cluster is done in the same manner as a PowerStore T

正解:C


質問 # 75
......

合格させるEMC DES-1241テスト練習問題 試験問題集:https://jp.fast2test.com/DES-1241-premium-file.html

ベストDCS-PE学習ガイドにはDES-1241試験問題集:https://drive.google.com/open?id=1rVwop6e-fLZjFEpy_Z3pniW-u-NFbV6Q


弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

我々の働いている時間: ( GMT 0:00-15:00 )
月曜日から土曜日まで

サポート: 現在連絡 

English Deutsch 繁体中文 한국어