質問 # 23
Which of the following is used to measure the length of a 4-pair cable?

  • A. Time domain reflectometer (TDR)
  • B. Pair scanner
  • C. Tone generator
  • D. Cable-end locator kit

正解:A


質問 # 24
Which of the following quantifies the bandwidth of a cabling system in a frequency range of interest?

  • A. Megabits
  • B. Megahertz
  • C. Volt-amperes
  • D. Kilowatt hours

正解:B


質問 # 25
Unqualified workers must stay AT LEAST ____ from exposed energized conductors operating at 300 to
50,000 V.

  • A. 15 m (50")
  • B. 3 m (10')
  • C. 30 m (100')
  • D. 0.3 m (1')

正解:B


質問 # 26
During the troubleshooting phase, what is the first step?

  • A. Test
  • B. Verify
  • C. Isolate
  • D. Repair

正解:B


質問 # 27
What is the size of a rack-mounted unit (RMU)?

  • A. 50 mm (2")
  • B. 45 mm (1.75")
  • C. 38 mm (1.5")
  • D. 25 mm (1")

正解:B


質問 # 28
Which of the following fire ratings refers to the time period that the unexposed surface of a firestop assembly does not exceed 180 degrees C (325 degrees F) above its initial temperature?

  • A. FT rating
  • B. E rating
  • C. S rating
  • D. FH rating

正解:A


質問 # 29
Which of the following steps should be performed first when terminating a coaxial cable?

  • A. Strip the cable
  • B. Verify connector type
  • C. Cut the cable
  • D. Fold back the braiding

正解:B


質問 # 30
What is the characteristic impedance of Series-6 coaxial cable?

  • A. 50 ohms
  • B. 25 ohms
  • C. 100 ohms
  • D. 75 ohms

正解:D


質問 # 31
What is the maximum permissible amount of untwisting for category 5e cable and higher?

  • A. 38 mm (1.5")
  • B. 75 mm (3")
  • C. 25 mm (1")
  • D. 12.7 mm (0.5")

正解:D


質問 # 32
What is the bend radius requirement for optical fiber cable when the cable is at rest?

  • A. 15 times the cables outside diameter
  • B. 10 times the cables outside diameter
  • C. 20 times the cables outside diameter

正解:B


質問 # 33
If the situation requires, a conduit should be terminated _______ the plywood backboard?

  • A. Through
  • B. Below
  • C. Above

正解:A


質問 # 34
Which type of cabling is installed between a main cross-connect (campus distributor) and an intermediate cross-connect (building distributor)?

  • A. Second-level backbone
  • B. First-level backbone
  • C. Horizontal

正解:B


質問 # 35
What method of transmission is used to transmit signals during a telephone call?

  • A. Half-duplex
  • B. Full duplex
  • C. Simplex

正解:B


質問 # 36
The horizontal distance from the base of the ladder to the supporting wall should be ____ percent the working length of the ladder.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:B


質問 # 37
Which of the following describes a nonmechanical firestop system that forms a hard char when exposed to flame?

  • A. Intumescent
  • B. Elastomeric
  • C. Ablative
  • D. Endothermic

正解:C


質問 # 38
You are pre-terminating cable. Where should the labels be placed?

  • A. Near end
  • B. Both ends
  • C. Far end

正解:B


質問 # 39
Which of the following must be measured before the length of a coaxial cable can be calculated?

  • A. Propagation delay
  • B. Insertion loss
  • C. Delay skew
  • D. DC loop resistance

正解:D


質問 # 40
Which of the following makes the biggest impression on a customer when you are communicating via email?

  • A. Body language
  • B. Tone of voice
  • C. Choice of words

正解:C


質問 # 41
Which type of cabling is installed between a main cross connect and a horizontal cross connect?

  • A. Second-level backbone
  • B. First-level backbone
  • C. Horizontal

正解:B


質問 # 42
What is the maximum pull force for four-strand optical fiber?

  • A. 330 N (75lbf)
  • B. 222N (50 lbf)
  • C. 880 N (200 lbf)

正解:B


質問 # 43
What is the primary purpose of firestopping?

  • A. Restore the barrier's original load-bearing capacity
  • B. Increase a facilities ability to detect fires
  • C. Reestablish the barrier's fire rating
  • D. Suppress fires before they can spread

正解:C


質問 # 44
Which tool is required to pull backbone cable of significant weight?

  • A. Tugger
  • B. Pulling eye
  • C. Furcating harness
  • D. Pull string

正解:A


質問 # 45
Which of the following is permissible if the available firestop assembly is NOT capable of properly restoring the necessary fire rating?

  • A. Obtain written assistance from the manufacturer
  • B. Move the installation to another location
  • C. Add more of the product to increase the rating
  • D. Substitute products from another assembly

正解:A


質問 # 46
......