NCM-MCI-5.15のPDF試験材料2022年最新の実際に出るNCM-MCI-5.15問題集 [Q14-Q31]

Share

NCM-MCI-5.15のPDF試験材料2022年最新の実際に出るNCM-MCI-5.15問題集

更新されたのはNutanix NCM-MCI-5.15問題集PDFオンラインエンジン


Nutanix NCM-MCI-5.15 認定試験の出題範囲:

トピック出題範囲
トピック 1
  • Given a scenario, troubleshoot connectivity issues
  • Given a scenario, upgrade firmwave
トピック 2
  • Configure networking for optimal performance
  • Given scenario, implement Nutanix Files
  • Given a scenario, troubleshoot storage
トピック 3
  • Given a scenario, troubleshoot network visualizations
  • Given a scenario, troubleshoot performance issues
トピック 4
  • Configure Data Protection to meet customer HA
  • DR requirements
  • Evaluate capacity Runways to predict growth
トピック 5
  • Configure security to leverage external authentication
  • authorization resources
  • Given a scenario, analyze cluster performance
トピック 6
  • Securing Traffic Through Network Segmentation
  • Given a scenario, troubleshoot issues using alerts and
  • or logs
トピック 7
  • Given scenario, optimize performance for specific workloads
  • onfigure security for Nutanix Enterprise Clouds
トピック 8
  • NX Series Hardware Administration Guide
  • Validate Disaster Recovery configurations

 

質問 14
An administrator needs to replace an aging SAN and move to a hyper-converged infrastructure. The existing environment consists of the following hosts that are connected to the SAN:
* 5xAIX hosts
* 3x Hyper-V hosts
* 9xESXi hosts
* 2x physical SQL Clusters (Windows Server 2012R2 hosts)
After deploying a Nutanix AHV cluster, which two actions should the administrator take to meet the requirements? (Choose two.)

  • A. Migrate the ESXI workloads to AHV using Move.
  • B. Deploy Files to support the AIX hosts.
  • C. Deploy Volumes to support the AIX and SQL workloads.
  • D. Migrate the ESXi and Hyper-V workloads using Move.

正解: C,D

解説:
Explanation
Ref: https://portal.nutanix.com/#page/kbs/details?targetId=kA00e000000Cr7GCAS

 

質問 15
An alert about RX errors on eth2 on a node is reported in the cluster. The administrator logs in to the CVM in question, checks the ping_* files in the data/logs/syststats folder, and notices intermittent ping loss.
The node in question has the following network configuration:

Which action should be used to troubleshoot without disrupting the VMs running on this node?

  • A. Remove eth3 from br0-up and monitor for new alerts
  • B. Enable balance-s1b on br0-up and monitor if a problem persists
  • C. Check the port on the switch side for any errors
  • D. Replace the cable from eth2 to the switch

正解: B

 

質問 16
A customer has a Nutanix cluster with 10Gb connectivity via switch fabric extenders. The administrator receives NCC health check errors of latency greater than 200ms.
Which action should the administrator take to resolve the NCC errors?

  • A. Upgrade NCC and increase the vCPU of the CVM
  • B. Add 2 additional 10G uplinks from the switch fabric extenders per node
  • C. Upgrade NCC and increase the CVM memory by 4Gb
  • D. Replace the switch fabric extenders with 10G line rate switches

正解: D

解説:
Explanation
Ref:
https://portal.nutanix.com/page/documents/details?targetId=System-Specs-G6-Single-Node:set-block-connect-c.

 

質問 17
A customer needs a DR solution designed around the following requirements:
* There are 8 ms of latency between Sites A and B
* The administrator needs the shortest RPO/RTO possible
* Application consistent snapshots are required
* Use of Nutanix VSS
Which Data Protection Method should be used?

  • A. Metro Availability
  • B. Near Sync
  • C. Cloud Connect
  • D. Async

正解: B

解説:
Explanation
Ref:
https://portal.nutanix.com/page/documents/details?targetId=Prism-Element-Data-Protection-Guide-v5_18:wc-d

 

質問 18
An administrator is deploying Nutanix Files 3.5 and needs to configure the sizing of the FSVMs for an increased number of concurrent SMB connections over the default 750.
What should the administrator do?

  • A. Complete the default installation change the CPU and RAM m Prism, and then log into the File Server dashboard and change the Filer Server Properties
  • B. During installation, click Customize on the File Server Installation screen, change the number of connections, and finish the installation
  • C. During installation, input the correct number of connections in the File Server Installation screen and complete the installation
  • D. Deploy the Files VMs. power down the three FSVMs. change the CPU and RAM via Prism, and then power the three FSVMs back up

正解: B

解説:
Explanation
Ref: https://portal.nutanix.com/page/documents/details?targetId=Files-v3_6:fil-file-server-manage-c.html

 

質問 19
An administrator needs to expand a cluster based on AHV and running on Nutanix G5 hardware with a new Nutanix G7 system. The cluster is running AOS 5.10 but the operation fails when expanding the cluster. AOS is running on the new system. There are no issues discovering the node.
Why is the operation failing?

  • A. G7 hardware cannot be added to a G5 cluster.
  • B. AOS version running on G7 is older than the version on the cluster.
  • C. Foundation software has not been updated on the cluster.
  • D. EVC needs to be configured before cluster expansion

正解: B

解説:
Explanation
Ref: https://next.nutanix.com/installation-configuration-23/product-mixing-restrictions-37231

 

質問 20
An administrator has a VM that consumes large amounts of storage and has the following characteristics:
* Create large / sequential writes
* Data must be kept for years
* Data is normally only accessed at the end of the year to run report
The administrator decides to use Erasure Coding to save space.
Which feature should the administrator utilize to save space for this VM?

  • A. Cache Dedup
  • B. Flash Mode
  • C. Post-Process Compression
  • D. Inline Compression

正解: C

 

質問 21
An administrator is configuring an All Flash cluster to support the following workloads:
* Full clone virtual desktops
* Hadoop
* Write heavy databases
Which three correct configuration options should the administrator use to meet the item requirements?
(Choose three.)
For each procedure, indicate whether it is a correct or incorrect procedure that must be configured to meet the item requirements using the drop-down option.

正解:

解説:

Explanation

Ref:

 

質問 22
A system administrator needs to shut down an AHV node in a Nutanix cluster without causing service disruption. The administrator checks data resiliency and verifies that the cluster can tolerate a node down.
Which three steps should the administrator perform next? (Choose three.)

正解:

解説:

Explanation
1 allow vms 2 sd CVM 3 sd node

 

質問 23
Refer to the exhibit.

An administrator is commissioning a Nutanix Enterprise Cloud. Once the user VMs have been deployed and are running, the administrator finds that VMs on the same host are able to communicate, but are unable to communicate between hosts.
What must be changed to enable full inter-VM communications?

  • A. Change the spanning-tree port type on the switch
  • B. Change the network the VMs are connected to
  • C. The VMs need to have static IP addresses
  • D. Update the switch to specifically allow VLAN 15

正解: D

解説:
Explanation
Ref: https://hyperhci.com/2019/11/09/nutanix-ahv-enable-vlan-trunk-mode-on-guest-vm/

 

質問 24
An administrator is configuring an All Flash cluster to support the following workloads:
* Full clone virtual desktops
* Hadoop
* Write heavy databases
Which three correct configuration options should the administrator use to meet the item requirements?
(Choose three.)
For each procedure, indicate whether it is a correct or incorrect procedure that must be configured to meet the item requirements using the drop-down option.

正解:

解説:

Explanation

Ref:

 

質問 25
An administrator needs to forecast infrastructure requirements for a new program and its associated applications. Prior to the projected start of the new program, all existing applications will be decommissioned.
How should the administrator perform this task?

  • A. Check the Disregard Existing Nodes radio button in the Runway scenario.
  • B. Check the Disregard Existing Workloads radio button in the Runway scenario.
  • C. Add up the recovered workloads and manually remove from the Runway configuration.
  • D. Power down the workloads during a maintenance window and run the Capacity Runway.

正解: B

 

質問 26
An administrator deletes a large amount of data from a Volume Group presented to a Linux VM. The administrator notices that the deleted data has not been reclaimed as usable storage.
What action should be taken to reclaim the storage capacity?

  • A. Enable the unman operation on the Linux VM
  • B. Unmount the Volume Group and then Remount the Volume Group
  • C. Run Defrag on the Linux VM
  • D. Shrink the Volume Group that is associated with the Linux VM

正解: B

解説:
Explanation
https://next.nutanix.com/how-it-works-22/vm-capacity-and-prism-capacity-are-different-33134

 

質問 27
An administrator protected a DB VM running on a Nutanix cluster with NearSync Replication, which schedules to repeat every 15 minutes to a second site. The daily change rate is low. During nightly backups, the replication window is missed due to write volume.
Which two options describe the expected behavior? (Choose two.)

  • A. NearSync stops working and fails over to the remote site.
  • B. The Administrator needs to re-enable it manually.
  • C. Protection Domain transitions back to the hourly schedule.
  • D. The system continuously tries to get to the NearSync schedule.

正解: A,D

 

質問 28
An administrator knows that the disks in a cluster are out of date and a new firmware is available. For security reasons, these clusters do not have access to the Internet.
Which two steps must be completed to update the firmware? (Choose two.)

  • A. Configure LCM with a URL to access the firmware bundle.
  • B. Select Upgrade Software, then select disks and upload the updated firmware.
  • C. Download the updated firmware .tgz file from the Nutanix portal.
  • D. Download a dark site bundle and stage it on an internal webserver.

正解: A,D

 

質問 29
Refer to the exhibit.

An administrator is commissioning a Nutanix Enterprise Cloud. Once the user VMs have been deployed and are running, the administrator finds that VMs on the same host are able to communicate, but are unable to communicate between hosts.
What must be changed to enable full inter-VM communications?

  • A. Change the spanning-tree port type on the switch
  • B. Change the network the VMs are connected to
  • C. The VMs need to have static IP addresses
  • D. Update the switch to specifically allow VLAN 15

正解: D

解説:
Explanation
Ref: https://hyperhci.com/2019/11/09/nutanix-ahv-enable-vlan-trunk-mode-on-guest-vm/

 

質問 30
An administrator receives an alert in Prism indicating that interface eth2, on an AHV host is receiving many CRC errors. After togging into the problematic host, the following command is run to show the indicated output:

What is causing this issue?

  • A. The interface is incorrectly configured with Jumbo Frames
  • B. A physical layer network problem
  • C. Incorrect link speeds on the switch
  • D. A misconfigured bond

正解: A

解説:
Explanation
Ref:
rx_crc_errors are caused either by faults in layer 1 (in the past, we have seen failed twinax cables and incorrect types of fibre being used), or issues with jumbo frames on the network. In an environment with 10 Gig switches that use cut-through forwarding (Cisco Nexus, Arista, Cisco devices using IOS default to Store and Forward switching), any packets that come into the switch will get forwarded out the destination interface once the switch has read the destination MAC address. If that packet has an MTU over what is configured on the interface, it will cut off the packet at the designated MTU, causing the server to receive a malformed packet, which will throw a CRC error.
If you have a layer 1 issue, you will see not on all but one or two nodes.

 

質問 31
......

Nutanix NCM-MCI-5.15問題集PDFのベストを目指すなら問題集を使おう!高得点目指すならここ:https://jp.fast2test.com/NCM-MCI-5.15-premium-file.html


弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

我々の働いている時間: ( GMT 0:00-15:00 )
月曜日から土曜日まで

サポート: 現在連絡 

English Deutsch 繁体中文 한국어