[2024年10月]更新のNutanix NCP-MCI-6.5日本語試験基本問題には解答が付きます
2024年最新の実際に出るNutanix NCP-MCI-6.5日本語試験問題集と解答
質問 # 12
管理者は、各ノードに次の構成を持つ 4 つのノードで構成される AHV クラスターを持っています。
CPU:2.4GHz、12コア各2
メモリー: 256GB
ディスク: 1.92 SSD 各 6
16 個の vCPU と 96 GB の RAM を備えた VM がクラスター上に作成されています。
管理者は、最適なパフォーマンスを確保するために VM をどのように構成する必要がありますか?
- A. メモリオーバーコミットあり
- B. フラッシュモードが有効の場合
- C. 2 つの vNUMA ノードを使用
- D. アフィニティ ポリシーあり
正解:C
解説:
The best way to configure the VM for optimal performance is to set it up with 2 vNUMA nodes. This will ensure that the VM is configured to take advantage of the CPU and memory resources available in each node, and it will also ensure that all of the cores are utilized for the best performance. Additionally, the administrator should ensure that the VM has an affinity policy set up so that the vCPUs are evenly distributed across the four nodes. Finally, Flash Mode should be enabled in order to take advantage of the high-performance SSDs that are available in the cluster
質問 # 13
資料を参照してください:
管理者は、すべての VM に対してカスタム アラート ポリシーを作成しようとしています。
フィールドがグレー表示されている場合にアラート警告が表示されるのはなぜですか?
- A. 動作異常のしきい値が設定されています。
- B. しきい値が設定されている場合のアラート クリティカル。
- C. [ポリシーを有効にする] オプションがオンになっています。
- D. [アラートの自動解決] オプションがオンになっています。
正解:A
解説:
when you create a custom alert policy, you can choose between two types of thresholds: Static Threshold and Behavioral Anomaly. Static Threshold allows you to set a fixed value for the metric that triggers the alert.
Behavioral Anomaly allows you to use machine learning to detect abnormal behavior based on historical data.
If you select Behavioral Anomaly as the threshold type, you cannot set a warning level for the alert. You can only set a critical level that indicates how much deviation from normal behavior is considered an anomaly3.
Therefore, the Alert warning if field is greyed out when you select Behavioral Anomaly.
質問 # 14
展示品を参照してください:
管理者は、Nutanix クラスターに以前にアップロードされたいくつかのイメージを更新する必要がありますが、Prism Element にログインしているときにイメージを更新しようとすると、更新アイコンが有効になりません。
この動作の原因は何でしょうか?
- A. 画像が Prism Central にインポートされました。
- B. RBAC が構成されていますが、管理者のユーザーには適切な権限がありません。
- C. ファイルは ISO ですが、ディスク イメージとしてアップロードされたため、使用または編集できません。
- D. 画像が破損しているため、再アップロードする必要があります。
正解:B
質問 # 15
管理者は、Nutanix ボリュームを介して接続された大量のデータを含むアプリケーションをデプロイする必要があります。
ボリューム グループを設計するときに管理者が実行する必要があるアクションを 2 つ選択してください。(2つ選んでください。)
- A. 複数の仮想ディスクにワークロードを分散します
- B. ボリューム グループでシック プロビジョニングを有効にします。
- C. RSS (Receive Side Scaling) を有効にする
- D. iSCSI トラフィックに複数のサブネットを使用する
正解:A、C
解説:
According to the Nutanix Volumes - Recommendations And Best Practices web search result3, two actions that the administrator should take when designing the Volume Group are:
Distribute workload across multiple virtual disks: Use multiple disks rather than a single large disk for an application. Consider using a minimum of one disk per Nutanix node to distribute the workload across all nodes in a cluster. Multiple disks per Nutanix node may also improve an application's performance. For performance-intensive environments, we recommend using between four and eight disks per CVM for a given workload.
Enable RSS (Receive Side Scaling): Receive-side scaling (RSS) allows the system to use multiple CPUs for network activity. With RSS enabled, multiple CPU cores process network traffic, preventing a single CPU core from becoming a bottleneck. Enabling RSS within hosts can be beneficial for heavy iSCSI workloads. For VMs running in ESXi environments, RSS requires VMXNET3 VNICs. For Hyper-V environments, enable VMQ to take full advantage of Virtual RSS.
質問 # 16
AHV クラスター上に VM を作成する場合、VM の初期配置はどのように決定されますか?
- A. 配置は、VM 作成時に new_VM トークンを保持するホストによって決定されます。
- B. 管理者は目的のホストを右クリックし、ドロップダウン メニューから [Power on VM] を選択します。
- C. AHV はラウンド ロビン アルゴリズムを使用し、UUID の番号順に基づいて新しい VM をホストに配置します。
- D. Acropolis Dynamic Scheduler は、VM 構成に適切なリソースを提供するホストを選択します。
正解:D
解説:
According to section 6 of the exam blueprint guide1, one of the topics covered is VM placement options. When creating a new VM on an AHV cluster, there are two ways to determine its initial placement:
Automatic placement: The Acropolis Dynamic Scheduler (ADS) selects a host that provides adequate resources for the VM's configuration, such as CPU, memory, disk space, and network bandwidth. ADS also considers factors such as host load, power state, availability domains, and affinity rules.
Manual placement: The administrator can specify a host or a host group where they want to place the VM.
質問 # 17
Prism Central は、AHV クラスターに手動でインストールされます。
Prism Central VM のポータルからダウンロードする必要がある 3 つのディスク イメージはどれですか? (3つ選んでください。)
- A. 変数
- B. データ
- C. ブート
- D. tmp
- E. ホーム
正解:B、C、E
解説:
https://portal.nutanix.com/page/documents/details?targetId=Prism-Central-Guide-Prism-v5_10:mul-pc-install-scratch-c.html According to the Nutanix Support & Insights web search result4, Prism Central can be installed manually on an AHV cluster by using three disk images: boot, home, and data. These disk images must be downloaded from the portal for the Prism Central VM and uploaded to an image service on the AHV cluster. The boot image contains the operating system and kernel for Prism Central. The home image contains the configuration files and logs for Prism Central. The data image contains the database and application files for Prism Central.
質問 # 18
効率と効果を最大化するために、スナップショットとクローンが利用するアルゴリズムはどれですか?
- A. リダイレクトオンライト
- B. 継続的なデータ保護
- C. スプリットミラー
- D. コピーオンライト
正解:A
質問 # 19
管理者は、一連の受信者に暗号化されたメッセージを送信するように Prism を構成する必要があります。
どの設定を適用する必要がありますか?
- A. SMTP ポート 25 を使用
- B. クラスター ロックダウンを使用するように Prism Central を構成します。
- C. Prism Central に SSL 証明書をインストールする
- D. SMTP セキュリティ モードを STARTTLS に設定します。
正解:D
解説:
Explanation
The best way for the administrator to configure Prism to send encrypted messages to a set of recipients is to set the SMTP Security Mode to STARTTLS. This will ensure that all messages sent over SMTP are encrypted and secure. Additionally, the administrator should consider installing SSL certificates on Prism Central to ensure that the messages are being sent securely. Finally, the administrator should consider configuring Prism Central to use Cluster Lockdown, which will help ensure that the messages are only sent to the intended recipients.
質問 # 20
管理者が VDI ソリューションを実装しています。ワークロードは、4 ノード クラスタ内の専用ストレージ コンテナ内の一連の永続的なデスクトップになります ノード障害イベント時を含め、最適なパフォーマンスを提供するために、専用ストレージ コンテナにストレージ最適化を設定する必要があります要件?
- A. 重複排除とイレイジャー コーディング
- B. 圧縮と重複排除
- C. 圧縮のみ
- D. 圧縮重複排除とイレイジャー コーディング
正解:D
解説:
According to the web search results, three storage optimizations that should be set on a dedicated storage container for a VDI solution with persistent desktops are compression, deduplication and erasure coding. Compression is a technique that reduces the size of data by removing redundant information. Deduplication is a technique that eliminates duplicate copies of data blocks and stores only unique blocks. Erasure coding is a technique that increases usable capacity by reducing the replication factor of data blocks and using parity information instead7. These three optimizations can improve performance and save storage space for VDI workloads, especially during a node failure event when data needs to be rebuilt from parity information8. The administrator can enable these optimizations by using Prism Element web console or ncli command-line interface9.
質問 # 21
管理者は、同じエンティティに適用されるいくつかのカスタム アラート ポリシーを作成しました。 Prism Central は、同様のポリシーが存在するというメッセージを表示します。
重複するポリシーはどのような優先順位で評価されますか?
正解:
解説:
Explanation:
First Preference:
* Policy is applied to a specific entity
2nd Preference:
* Policy is applied to an entity type in a category
3rd Preference:
* Policy is applied to an entity type in a cluster
4th Preference:
* Policy is applied to all entities of an entity type
Comprehensive Detailed Explanation with References:In Nutanix Prism, when multiple alert policies are created and applied to the same entities, the policies are evaluated based on their specificity. The order of precedence from highest to lowest is as follows:
* Policy is applied to a specific entity: Custom alert policies that are applied to specific entities take precedence over those applied to broader categories. This is because the more specific policy is usually created with a particular context or requirement in mind for that entity.
* Policy is applied to an entity type in a category: The next level of precedence is given to policies that are applied to all entities of a certain type within a specific category. Categories allow grouping of entities based on certain criteria, and policies applied here are more specific than to an entire cluster or entity type.
* Policy is applied to an entity type in a cluster: This refers to policies that are applied to all entities of a certain type within a specific cluster. This is more general than the above two but still targets a specific cluster environment.
* Policy is applied to all entities of an entity type: The lowest precedence is given to policies that are broadly applied to all entities of a particular type across the entire Nutanix environment.
This order ensures that the most specifically targeted policies are given priority, which allows for fine-tuned control and customization of alert policies. The details of alert policy precedence are typically covered in the Nutanix Prism Central Guide and the documentation related to Prism Central's alerting and policies.
質問 # 22
ホットスポットを排除して再構築を高速化するために、クラスター全体にデータを均一に分散させるコンポーネントはどれですか?
- A. 高可用性
- B. Acropolis アプリ モビリティ ファブリック
- C. 分散ストレージ ファブリック
- D. カサンドラ
正解:C
解説:
According to the web search results, Distributed Storage Fabric (DSF) is the scale-out storage technology that makes HCI and cloud possible45. DSF pools the storage devices that are directly attached to a cluster of servers and presents them to applications across a variety of storage protocols4. DSF also manages and protects data by a fine-grained, distributed metadata system that ensures uniform distribution of data throughout the cluster to eliminate hot spots and speed up rebuilds
質問 # 23
管理者は、次の構成を持つ Nutanix AHV クラスターで、ブロック認識を有効にして耐障害性を FT2 に高めるよう求められました。
4ブロック
ブロックごとに 1 つのノード
管理者はこれらのタスクを実行できますか?
- A. はい - ブロック認識には最低 3 つのブロックが必要です。
- B. No-Fault tolerance の変更はサポートされていません。
- C. はい。FT2 には最低 3 つのノードが必要です。
- D. No-FT2 には、最低 5 つのノードが必要です。
正解:D
質問 # 24
管理者は、VM がストレージ ファブリックに対して読み書きするデータの量を懸念しています。
そのデータを提供する指標はどれですか?
- A. VM ストレージ コントローラーの IOPS
- B. ホスト ディスク IOPS
- C. ホスト ハイパーバイザーの IO 帯域幅
- D. VM ストレージ コントローラーの帯域幅
正解:A
質問 # 25
管理者は VM を新しい Nutanix クラスターに移行します。移行後、管理者は次の条件を観察します。
* クラスターのメモリ使用率: 64%
* クラスターの CPU 使用率: 19%
* クラスタ ストレージの使用率。32%
* 平均 VM CPU 使用率: 25%
* 平均 VM CPU Ready%: 24%
* 平均 VM メモリ使用率: 60%
VM のパフォーマンスを向上させるために管理者が行う必要がある 2 つの変更はどれですか? (2つ選んでください。)
- A. VM に割り当てる vCPU の数を減らします。
- B. ホスト上の VM の数を減らします。
- C. VM にメモリを追加します。
- D. コア数の多い CPU をクロック レートの高い CPU に置き換えます。
正解:A、B
解説:
According to the CPU (%) - VMware Docs web search result2, one of the possible causes of high CPU ready
% is over-provisioning vCPUs for a VM or having too many VMs on a host. CPU ready % indicates the percentage of time that the VM was ready, but could not get scheduled to run on the physical CPU. High CPU ready % can lead to VM performance problems, such as slow response time or application latency. To improve VM performance, the administrator should reduce the number of vCPUs assigned to VMs or reduce the number of VMs on the hosts, so that there is less contention for CPU resources.
質問 # 26
管理者は、AHV ホストと CVM が利用できる帯域幅を増やす必要があります。
管理者はこのタスクをどのように完了する必要がありますか?
- A. manage-ovs コマンドを使用して、br0 を更新し、構成を Active-Active に変更します。
- B. Prism で、vsl インターフェイスを作成し、残りのアップリンクを追加します。
- C. manage-ovs コマンドを使用して br1 を作成し、残りのアップリンクを追加します。
- D. Prism で、vs0 を更新して構成を Active-Active に変更します。
正解:A
解説:
The default network configuration for AHV hosts and CVMs is a bond named br0-up with two or more uplinks in active-backup mode. This means that only one uplink is active at a time, while the others are in standby mode. This provides high availability, but not load balancing or increased bandwidth. To increase the bandwidth available to the AHV host and the CVM, the administrator can change the bond mode to Active-Active, which allows all uplinks to be used simultaneously. This can be done using the manage-ovs commands on each AHV host. The steps are as follows1:
Log in to the AHV host using SSH.
Enter maintenance mode on the CVM by running allssh 'cluster status | grep -i cvm | grep -i down'.
Change the bond mode to Active-Active by running manage_ovs --bond_mode active-active update_uplinks br0-up <uplink_list>, where <uplink_list> is a comma-separated list of uplink interfaces (for example, eth0,eth1).
Verify the bond mode by running manage_ovs show_uplinks.
Exit maintenance mode on the CVM by running allssh 'cluster start'.
質問 # 27
管理者が Nutanix サポート ポータルにログインすると、利用可能な LCM フレームワークの新しいバージョンがあることに気付きます。LCM が最新の機能を提供していることを確認するために、管理者は LCM をアップグレードしたいと考えています。
LCM フレームワークはどのようにアップグレードできますか?
- A. Prism のアップグレード ソフトウェアを介して最新の LCM フレームワーク バンドルをアップロードします。
- B. 最新の LCM フレームワークをイメージとして Prism のイメージ構成にアップロードします。
- C. AOS のアップグレード
- D. LCM インベントリを実行します。
正解:D
解説:
LCM (Life Cycle Manager) is a feature that allows Nutanix administrators to perform one-click firmware and software upgrades for Nutanix clusters and components. LCM fetches inventory and update information from a pre-configured URL that contains the latest versions of firmware and software packages. However, upgrading Nutanix AOS does not automatically update the fetch URL. To update the fetch URL, the administrator needs to update the LCM framework. The LCM framework is the core component of LCM that provides the logic and functionality for inventory, download, and upgrade operations1.
To upgrade the LCM framework, the administrator needs to perform an LCM inventory. An LCM inventory is a process that scans the cluster and its components for their current firmware and software versions and compares them with the available versions from the fetch URL. If there is a newer version of the LCM framework available, it will be shown as an update option under Cluster Software Component in the Available Updates page. The administrator can then select and apply the LCM framework update to upgrade it to the latest version2.
The administrator can perform an LCM inventory using Prism Element or Prism Central. The steps are as follows3:
In Prism Element, go to the Network Configuration page and click Life Cycle Management.
In Prism Central, go to the Services page and click Life Cycle Management.
Click Inventory in the toolbar and select Perform Inventory from the drop-down menu.
Wait for the inventory process to complete and check for any available updates.
質問 # 28
管理者は、起動可能な CD から VM を起動する必要があります。管理者は、VM を起動するように VM を構成しようとし、ディスクの追加を選択して、使用可能なイメージに移動します。ブータブル CD のイメージが利用できません。
可能性が高い問題とは何ですか?
- A. CD から起動するには、VM に標準ディスクを接続する必要があります。
- B. 管理者は、CD から起動する前に接続されたディスクを選択しました。
- C. CD-ROM インターフェイスが遅すぎます。
- D. 作成中にブータブル CD イメージが破損しました。
正解:B
質問 # 29
管理者は、クラスターの障害ドメイン レベルを拡張したいと考えています。
利用可能な2つのオプションは何ですか? (2つ選んでください。)
- A. ラック
- B. データセンター
- C. ノード
- D. ブロック
正解:A、D
解説:
Nutanix clusters are resilient to a drive, node, block, and rack failures because they use redundancy factor 2 by default, allowing Nutanix clusters to self-heal2. Failure scenarios can be thought of in terms of fault domains, which are the physical or logical parts of a computing environment or location that are adversely affected when a device or service experiences an issue or outage3. There are four fault domains in a Nutanix cluster:
Disk, Node, Block, and Rack4. Block and Rack are two options that are available for expanding the failure domain level of a cluster. Block fault tolerance is enabled by default and ensures that data is replicated across different blocks in a cluster5. Rack fault tolerance has to be configured manually and ensures that data is replicated across different racks in a cluster4.
References: 1: Behavioral Learning Tools - Prism Central Resource Management - Nutanix 2: How Nutanix Handles Failures | Node Failure 3: Failure Domain Considerations - Nutanix Support & Insights 4:
[Understanding Fault Domains and Rack Awareness - Nutanix] 5: [Nutanix Cluster Architecture Overview - Nutanix Bible]
質問 # 30
......
合格保証付きのNutanix Certified Professional NCP-MCI-6.5日本語試験問題集:https://jp.fast2test.com/NCP-MCI-6.5-JPN-premium-file.html