[2023年06月]更新のBICSI INSTC_V7公式認定ガイドPDF [Q26-Q48]

Share

[2023年06月]更新のBICSI INSTC_V7公式認定ガイドPDF

試験INSTC_V7 BICSI Installer 2 - Copper Exam

質問 # 26
Which of the following is used to equalize potential differences between the SBB on the same floor?

  • A. RBB
  • B. TBB
  • C. BBC
  • D. TEBC

正解:C


質問 # 27
A radio station transmits an omnidirectional signal that is received by multiple radios. What type of transmission method is used in this example?

  • A. Full-duplex
  • B. Half-duplex
  • C. Simplex

正解:C


質問 # 28
Cavity boxes should be at least _____ away from the wall, where possible.

  • A. 150mm (6")
  • B. 300mm (12")
  • C. 100mm (4")
  • D. 450mm (18")

正解:C


質問 # 29
Which of the following is used to connect cabinets to the nearest SBB?

  • A. RBB
  • B. TBB
  • C. BBC
  • D. TEBC

正解:D


質問 # 30
What method of transmission is used to transmit signals during a telephone call?

  • A. Full duplex
  • B. Half-duplex
  • C. Simplex

正解:A


質問 # 31
Which type of optical fiber cable should be color coded with a RED outer cable sheath?

  • A. Dispersion-shifted SM optical fiber
  • B. MM optical fiber with 50 um core diameter
  • C. Polarization maintain SM optical fiber
  • D. MM optical fiber with 50 um core diameter (laser-optimized)

正解:A


質問 # 32
Which of the following tend to cause sheath damage during cable pulling?

  • A. RMC/IMC
  • B. FMC/FMT
  • C. EMT/ENT

正解:B


質問 # 33
Which of the following steps should be performed first when an installer is pulling backbone cable from the bottom up?

  • A. Move cable reels into place
  • B. Determine appropriate rope size
  • C. Verify the proper cable run
  • D. Label cables and reels

正解:C


質問 # 34
A third 90-degree bend may be permitted in a conduit run if one of the bends is located within ____ of the cable feed end?

  • A. 450 mm (18")
  • B. 375 mm (15")
  • C. 300 mm (12")
  • D. 483mm (19")

正解:C


質問 # 35
You are terminating a category 3 cable. What is the maximum permissible amount of untwisting?

  • A. 75 mm (3")
  • B. 25 mm (1")
  • C. 38 mm (1.5")
  • D. 100 mm (4")

正解:A


質問 # 36
Light pulses in optical fiber cables are subjected to a loss in power as the light pulses travel along the optical fiber. Which of the following terms is used to describe this phenomenon?

  • A. Grounding
  • B. Frequency
  • C. Attenuation
  • D. Crosstalk

正解:C


質問 # 37
Which of the following is a measure of the amount of information being transported over media?

  • A. Megahertz
  • B. Megabits
  • C. Kilowatt hours
  • D. Volt-amperes

正解:B


質問 # 38
How much cable slack should be left in the work area after termination?

  • A. 3m (10')
  • B. 0.5m (1.6')
  • C. 1.2 m (4')
  • D. 1m (3.3')

正解:D


質問 # 39
What is the size of a rack-mounted unit (RMU)?

  • A. 25 mm (1")
  • B. 38 mm (1.5")
  • C. 45 mm (1.75")
  • D. 50 mm (2")

正解:C


質問 # 40
How long does it take someone to form a first impression?

  • A. 5 to 10 minutes
  • B. 30 minutes to 1 hour
  • C. 10 to 15 seconds
  • D. 1 to 2 minutes

正解:C


質問 # 41
What is the maximum allowable horizontal cable length?

  • A. 30 m (100')
  • B. 10 m (33 ')
  • C. 50 m (164')
  • D. 90 m (295')

正解:D


質問 # 42
Which topology uses a linear configuration that places all network devices on one length of cable?

  • A. Bus
  • B. Star
  • C. Ring

正解:A


質問 # 43
What is the minimum inside bend radius for balanced twisted pair (multi-pair) cable?

  • A. 6 times the outside cable diameter
  • B. 25 mm (1")
  • C. 10 times the outside cable diameter
  • D. 50 mm (2")

正解:C


質問 # 44
Which of the following must be measured before the length of a coaxial cable can be calculated?

  • A. Insertion loss
  • B. Delay skew
  • C. Propagation delay
  • D. DC loop resistance

正解:D


質問 # 45
What type of connector is used with ribbon cable?

  • A. Array
  • B. MPO
  • C. N Connector
  • D. F Connector

正解:A


質問 # 46
During the troubleshooting phase, what is the first step?

  • A. Verify
  • B. Isolate
  • C. Test
  • D. Repair

正解:A


質問 # 47
Which of the following is a floor serving space that serves as a point of termination for horizontal and backbone cables?

  • A. ER
  • B. TR
  • C. Work area
  • D. EF

正解:B


質問 # 48
......

無料INSTC_V7試験問題集試験点数を伸ばそう:https://jp.fast2test.com/INSTC_V7-premium-file.html

2023年最新の実際に出るINSTC_V7問題集には試験のコツがあるPDF試験材料:https://drive.google.com/open?id=1U7xId1bL7EHg1lbDMrZnEzRDc7X4yKid


弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

我々の働いている時間: ( GMT 0:00-15:00 )
月曜日から土曜日まで

サポート: 現在連絡 

English Deutsch 繁体中文 한국어