[2022年03月]更新のVMware 5V0-22.21実際のブレーン知能問題集 [Q41-Q63]

Share

[2022年03月]更新のVMware 5V0-22.21実際のブレーン知能問題集

合格できる5V0-22.21試験更新された5V0-22.21試験問題集PDFを獲得2022年更新


VMware 5V0-22.21 認定試験の出題範囲:

トピック出題範囲
トピック 1
  • Given a scenario, identify how to apply patches using vSphere Lifecycle Manager (LCM)
  • Identify how to monitor vSAN storage policy compliance
トピック 2
  • Identify how to configure vSAN stretched cluster and 2-node configurations
  • Identify how to configure Cloud Native storage (CNS) with appropriate policies
トピック 3
  • Given a scenario, identify how to create and remove vSAN Direct Configuration
  • Identify the architectural requirements of a standard vSAN cluster, vSAN 2-node cluster, and a vSANstretched cluster
トピック 4
  • Given a scenario, identify how to configure vSAN cluster services
  • Identify how to gather vSAN performance information in the UI or using vsantop
トピック 5
  • Identify the characteristics of the different types of encryption
  • Identify which VMware solutions integrate with vSAN
トピック 6
  • Given a scenario, identify how VMware solutions integrate with vSAN
  • Identify how vSAN stores and protects data
トピック 7
  • Given a scenario, identify how to upgrade an HCI environment using vSphere Lifecycle Manager (vLCM)
  • Identify the impact of vSAN storage policy changes
トピック 8
  • Identify Data Persistence platform (DPp) deployment options
  • Identify Data Persistence platform (DPp) deployment options
トピック 9
  • Identify how to use Skyline health check to maintain a healthy status of a vSAN cluster
  • Given a scenario, identify when and how to use vSphere Replication in combination with vSAN
トピック 10
  • Given a scenario, identify how to configure vSAN storage policies
  • Identify how to monitor vSAN with vRealize Operations
トピック 11
  • Identify how to create, update, and modify vSAN storage policies and apply to objects
  • Identify how to utilize TRIM and UNMAP from vSAN and guest OS perspective

 

質問 41
A vSAN administrator was presented with 30 additional vSAN ReadyNodes to add to an existing vSAN cluster. There is only one administrator to complete this task.
What is the fastest approach?

  • A. Use a Host Profile that was extracted from an existing host.
  • B. Clone the ESXi boot partition to all new hosts, since the hardware is identical.
  • C. Run vim-cmd to capture, and apply the configuration from an existing host.
  • D. Launch Quickstart to Add Hosts to a vSAN Cluster

正解: D

 

質問 42
A 5-node vSAN cluster contains multiple virtual machines, and a vSAN storage policy with the rule "Failures to tolerate" set to "1 failure - RAID-5 (Erasure Coding)" is assigned. A vSAN administrator has changed the rile in the assigned policy to "2 failures - RAID-6 (Erasure Coding)".
What is the result of this change?

  • A. Changes are queued for 60 minutes.
  • B. The updated policy is serially applied to the virtual machines.
  • C. No changes occur until the policy is reapplied.
  • D. The policy change is rejected immediately.

正解: A

 

質問 43
Which tool should be used to identify vSAN unassociated objects?

  • A. PowerCLI
  • B. vsantop
  • C. vSphere Host Client
  • D. vSphere CLI

正解: D

 

質問 44
Which state is NOT a compliance status of a VM Storage Policy?

  • A. Not Applicable
  • B. Compliant
  • C. Stale
  • D. Noncompliant

正解: C

 

質問 45
A host in the cluster experiences a permanent NIC failure, and the replacement part will not arrive until the next morning. The administrator needs to ensure the availability of the production workload at all times.
Which step should be taken by the administrator to meet this goal?

  • A. Enter Maintenance Mode with 'Full Data Migration'
  • B. Disable the vSAN Service on the VMkernel port.
  • C. Perform a live vMotion to another host.
  • D. Shut down the production VMs.

正解: C

 

質問 46
An existing vSAN cluster has this specification:
Four ESXi hosts with all flash configuration
Each with two disk groups
Each disk group with one cache device and four capacity devices
There are five more device slots available
The CTO would like to provision new applications, and these will need more capacity and performance.
Which two methods may be used by the vSAN administrator to meet this goal? (Choose two.)

  • A. Adding an ESXi host with identical device configuration
  • B. Adding faster cache devices
  • C. Replacing all cache devices by a larger device
  • D. Replacing all capacity devices by a larger device
  • E. Adding one more disk group per host with the same configuration

正解: A,E

 

質問 47
A vSAN administrator is tasked to perform an upgrade of a vSAN cluster from 7.0 to 7.0 U2, including firmware and drivers for its hardware. The vSAN administrator already created an image using vSphere Lifecycle Manager (vLCM).
Prior to selecting Start Remediation, which step should be taken to upgrade the complete vSAN cluster as a single task?

  • A. Manually remediate one host at a time in the vSAN cluster.
  • B. Select Remediate All through vLCM to upgrade all hosts in the cluster.
  • C. Place all hosts in the vSAN cluster into Maintenance Mode.
  • D. Stage the upgrade of the vSAN cluster through vLCM.

正解: A

 

質問 48
An administrator is enabling vSphere HA and vSAN on the same cluster and needs to use a configuration that is valid for vSphere HA Heartbeat datastore.
Which configuration should be used?

  • A. A datastore mounted to more than one host, as well as any vSAN datastore
  • B. vSAN datastore as vSphere HA Heartbeat datastore
  • C. Any datastore mounted to more than one host, but not a vSAN datastore
  • D. Any datastore mounted to more than one host

正解: C

 

質問 49
A vSAN administrator is looking at adding a new vSAN cluster with hosts that have 512GB memory.
What is the minimum requirement for the node's flash boot device?

  • A. 4GB
  • B. 128GB
  • C. 16GB
  • D. 32GB

正解: C

 

質問 50
An organization wants to configure a new storage policy based on the following requirements:
Failures to tolerate = FTT 1/RAID-5 (Erasure Coding)
Number of disk stripes per object = 8
IOPS limit for object = 0
Object Space Reservation = Thin provisioning
Flash read cache reservation = 0%
Disable object checksum = No
Force provisioning = No
The administrator creates the policy using storage policy based management and assigns it to a 100GB virtual machine on a 4-node vSAN cluster to test the results of the new storage policy.
How many components will be created per host for the storage objects of the virtual machine on the vSAN datastore?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解: A

 

質問 51
After a recent data loss event, the IT department plans to deploy a DR site using vSphere Replication with vSAN providing the storage backend.
The architect would like to know how many components will be created based on the following configuration:
2x 100 GB VMDK
RAID 1 vSAN Storage Policy
4x Point in Time snapshots
How many components will be created?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解: D

 

質問 52
What os the maximum number of 2-node clusters that can share a vSAN Shared Witness host in vSAN 7.0 U1?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解: A

 

質問 53
The Resyncing Objects view in the vCenter UI reports that some objects are currently resyncing.
Which two actions would cause this situation? (Choose two.)

  • A. A change to the storage policy is applied to the objects.
  • B. A VM snapshot is being deleted.
  • C. DRS is relocating VMs between vSAN nodes.
  • D. HA Virtual Machine Monitoring forced a VM to reboot.
  • E. A host failure occurs in the cluster.

正解: A,E

 

質問 54
When attempting to add a directly attached disk device to a host disk group, the intended disk does not show among the available devices in disk management.
Which action should be taken?

  • A. Create a 1GB metadata partition
  • B. Create a VMFS partition
  • C. Delete all device partitions
  • D. Format the existing partition

正解: C

 

質問 55
A new vSAN Cluster with four hosts has to be designed for a single site architecture.
Which design decision is correct?

  • A. Only hardware listed on the VMware Compatibility Guide will be deployed.
  • B. Configure the storage controllers to use RAID.
  • C. Use block-based storage for the newvSAN cluster.
  • D. All the data must remain accessible even with two host failures.

正解: B

 

質問 56
All of the virtual machines running on a hybrid vSAN datastore have this storage policy assigned:
Failures to Tolerate (FTT) rule is set to "2 Failures - RAID-1 (Mirroring)".
The vSAN administrator needs to reduce the amount of vSAN datastore capacity the virtual machines will consume.
Which action should the vSAN administrator take to meet this goal?

  • A. Add the "Flash read cache reservation" rule to the storage policy, and set to 0%.
  • B. Disable Operations reserve and Host rebuild reserve and click "Apply".
  • C. Change the FTT rule to "1 Failure - RAID-1 (Mirroring)", and select "Now" for Reapply to VMs.
  • D. Modify the FTT rule to "2 Failures - RAID-5 (Erasure Coding)".

正解: C

 

質問 57
A vSAN administrator has recently upgraded a vSAN cluster to 7.0 U1 and has enabled Capacity Reserve features to reduce the amount of capacity reserved for transient and rebuild operations.
Which scenario would prevent this feature from operating properly?

  • A. Underutilized space is above 25-30% of the total capacity threshold.
  • B. The used space on vSAN datastore exceeds the suggested slack rebuild threshold.
  • C. The used space on vSAN datastore exceeds the suggested host rebuild threshold.
  • D. The physical disk has reached an 80% full reactive rebalance threshold.

正解: A

 

質問 58
An administrator has successfully deployed a new 3-node vSAN Cluster. Prior to deploying any production workloads on to the new cluster, the administrator must complete a number of Service Validation and Testing (SVT) checks.
The final check requires the administrator to pull out a disk from one of the vSAN hosts.
Which two outcomes will occur within the vSAN cluster following this action? (Choose two.)

  • A. By default. vSAN will start the rebuilding of affected components immediately.
  • B. All components on the device will be marked as degraded.
  • C. All components on the device will be marked as absent.
  • D. By default vSAN will delay the rebuilding of affected components for 30 minutes.
  • E. By default. vSAN will delay the rebuilding of affected components for 60 minutes.

正解: A,B

 

質問 59
A remote location was configured with Cloud Native Storage. When the administrator put the host in maintenance mode to perform monthly patching, the File Server Health check was triggered.
Which action, if any, should the administrator take to resolve the issue?

  • A. It will resolve after 60 seconds, so no action is necessary.
  • B. Click the Repair Objects Immediately button in the VMware Skyline Health Checks.
  • C. Remove the host from maintenance mode, and put it back with Full Data Migration.
  • D. Modify the repair delay timer to 75.

正解: B

 

質問 60
Which two characteristics are associated with vSAN Data-In-Transit Encryption? (Choose two.)

  • A. Uses AES-256 bit encryption
  • B. Can be enabled independently of the vSAN Data-At-Rest encryption
  • C. Requires an external KMS in order to work
  • D. Needs specific configuration on the Network switches in order to be enabled
  • E. Needs to be enabled using vSAN Storage Policies

正解: A,B

 

質問 61
An administrator is responsible for managing a 5-node vSAN 7.0 cluster that hosts 150 virtual machines. Each virtual machine belongs to one of the following vSAN Storage Policies:
vSANPolicy1:
Site Disaster Tolerance: None
Failures to Tolerate: 1 failure - RAIN5 (Erase Coding)
vSANPolicy2:
Site Disaster Tolerance: None
Failures to Tolerate: No data redundancy
Following an unplanned power event within the datacenter, the administrator has been alerted to the fact that one host has permanently failed. Prior to the vSAN host failure, the usable storage capacity of the vSAN Cluster was more than 40%.
What will be the potential impact to any virtual machine that was running on the failed host using vSANPolicy2?

  • A. vSAN will immediately start the recovery process.
  • B. Each virtual machine will need to be restored from backup.
  • C. Each virtual machine will be restarted on another vSAN host using vSphere HA.
  • D. After 60 minutes, vSAN will automatically start the recovery process.

正解: B

 

質問 62
An administrator will be performing a rolling upgrade of a vSAN cluster over the weekend. In preparation, the administrator runs the Data Migration Pre-Check.
Which two items are being checked? (Choose two.)

  • A. DRS settings
  • B. Affinity rules
  • C. Object compliance and accessibility
  • D. vSphere HA state
  • E. Cluster capacity

正解: C,E

 

質問 63
......

更新された5V0-22.21パスして合格保証試験問題集正確で更新された問題:https://jp.fast2test.com/5V0-22.21-premium-file.html

5V0-22.21試験知能問題集で学習ノートと理論:https://drive.google.com/open?id=1d6YilBtMGL41o4w8zQNdrQO2VEQh4UGP


弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

我々の働いている時間: ( GMT 0:00-15:00 )
月曜日から土曜日まで

サポート: 現在連絡 

English Deutsch 繁体中文 한국어