検証済みH19-338問題集と解答で2021年最新のH19-338をダウンロード [Q94-Q110]

Share

検証済みH19-338問題集と解答で2021年最新のH19-338をダウンロード

更新された100%カバー率リアルH19-338試験問題で100%合格保証付いてます

質問 94
Which statements about the SmartTier feature for FS are NOT true? (Multiple choice)

  • A. The scope of the SmartTier feature of the FS is a single pool.
  • B. The media in the FS SmartTier feature are divided into three layers SSD, SAS, and NL-SAS.
  • C. The migration unit of the FS SmartTier feature is Extent.
  • D. The SmartTier features of the FS can define the migration rate.

正解: A,B,C,D

 

質問 95
Which technologies are used to improve Dorado performance? (Multiple choice)

  • A. I/O priority scheduling policy that assigns different priorities for different types of I/Os.
  • B. Full-strip write
  • C. Wear leveling and anti-wear leveling technologies.
  • D. RAID-IP
  • E. CPU grouping algorithm that uses dedicated cores for I/O reads and writes.

正解: A,B,E

 

質問 96
What is the purpose of using sequential I/Os to overwrite all LUNs before testing Dorado performance?

  • A. To ensure that all space of thin LUNs is allocated so read performance is close to that in actual scenarios
  • B. To ensure correct deduplication and compression ratios
  • C. To provide better performance

正解: C

 

質問 97
Which statements about FusionStorage are true? (Multiple Choice)

  • A. It employs a distributed cluster architecture.
  • B. It can be scaled out to a maximum of 4096 nodes.
  • C. It provides background data consistency checks.
  • D. It stores metadata in metadata nodes.

正解: A,B,C,D

 

質問 98
Which is the protocol for networking a smart disk enclosure with controller enclosures?

  • A. PCIe
  • B. FC
  • C. SAS
  • D. 100GE RoCE

正解: D

 

質問 99
After the SSD is removed the dirk domain of the OceanStor Dorado V3 (same with Dorado V6) storage system reconstructs data immediately.

  • A. True
  • B. False

正解: A

 

質問 100
In database application scenarios, which is the recommended latency of the active-active (HyperMetro) replication network?

  • A. 0
  • B. 1
  • C. 2
  • D. 0.5

正解: A

 

質問 101
In an OceanStor Dorado V6 Architecture with two controller enclosures and eight controllers, which scenarios are supported for high availability? (Multiple Choice)

  • A. Tolerance of simultaneous failures for any three controllers
  • B. Tolerance of simultaneous failures of any two controllers
  • C. Tolerance of simultaneous failures for seven controllers
  • D. Tolerance of a single controller enclosure failure

正解: A,B

 

質問 102
The active-active status will be interrupted if a quorum server is faulty.

  • A. True
  • B. False

正解: B

 

質問 103
Which of the following is the minimum RAID unit of Huawei RAID 2.0+?

  • A. Block (chunk)
  • B. Cache
  • C. Disk

正解: A

 

質問 104
Which of the following are the three levels of SSD wear? (Multiple choice)

  • A. Severe wear > 85%
  • B. Moderate wear: 50% <&&<85%
  • C. Mid-wear < 25%
  • D. Mid wear < 50%

正解: A,B,D

 

質問 105
Which of the following chips are part of the Dorado V6 in addition to Dorado V3's self-developed chips? (Multiple choice)

  • A. SSD controller chip
  • B. CPU chip
  • C. Multi-protocol interface chip
  • D. BMC chip
  • E. AI chip

正解: A,B,C,D,E

 

質問 106
Dorado V3 (same with Dorado V6) supports three kinds of RAID types _____, and the default RAID type is ______, while _____ supports triple disk failure.

  • A. RAID-5/RAID-6/RAID-TP; RAID-6; RAID-TP
  • B. RAID-5/RAID-6/RAID-TP; RAID-5; RAID-TP
  • C. RAID-5/RAID-6/RAID-10; RAID-5; RAID-10

正解: A

 

質問 107
Which statement about the ROW technology for OceanStor V5 is true?

  • A. ROW-based snapshots do not have extra data copies, and therefore the performance is better.
  • B. One of the advantages of ROW is that it does not easily generate data fragments
  • C. Block snapshots use the ROW technology

正解: A

 

質問 108
What facts can be used to clear customers' security concerns about SmartIDC-Grad (Information Collection) ? (Multiple Choice)

  • A. SmartIDC-Grab has been tested and certified by professional antivirus and security vulnerability scan tools.
  • B. Success stories
  • C. Only open APOs and CLI commands of the collected devices are invoked.
  • D. No plug-in is installed.

正解: A,C,D

 

質問 109
Which functions can be implemented by the host multipathing software? (Multiple Choice)

  • A. Failover
  • B. Load balancing
  • C. Failback

正解: A,B,C

 

質問 110
......

リアル問題集で100%無料H19-338試験問題集を試そう:https://jp.fast2test.com/H19-338-premium-file.html

実際のH19-338問題集最新練習テスト問題集:https://drive.google.com/open?id=1xRLA_0L46v7sSCOFL-zQA9gckCdp89qN


弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

我々の働いている時間: ( GMT 0:00-15:00 )
月曜日から土曜日まで

サポート: 現在連絡 

English Deutsch 繁体中文 한국어