検証済みCSDB問題集と解答100%合格はここにFast2test [Q64-Q83]

Share

検証済みCSDB問題集と解答100%合格はここにFast2test

合格させるCSDB試験一発合格保証2026問題集!

質問 # 64
Internal treatments for penetrating damp (when external repairs are not possible) should:

  • A. Be considered only if external repairs cannot be made, with appropriate membranes installed behind affected linings
  • B. Always be the first option
  • C. Be used alone without external investigation
  • D. Never be used

正解:A


質問 # 65
A damp proof course (DPC) in traditional construction serves to:

  • A. Support the roof only
  • B. Provide insulation only
  • C. Provide structural strength only
  • D. Prevent moisture rising from the ground through capillary action

正解:D


質問 # 66
Photographic evidence in a dampness report should:

  • A. Be purely decorative
  • B. Show typical areas of damp, close-ups of specific defects, and reference photographs for context
  • C. Never be included
  • D. Only show perfect conditions

正解:B


質問 # 67
Black mould associated with condensation can be temporarily removed by:

  • A. Leaving it untreated
  • B. Ignoring it
  • C. Cleaning with appropriate disinfectants; however, prevention through controlling condensation is more important
  • D. Painting over it

正解:C


質問 # 68
Cavity wall insulation can trap moisture if:

  • A. It is not installed correctly or if the cavity ventilation is blocked
  • B. It is too thick
  • C. It is installed during summer
  • D. It is grey in colour

正解:A


質問 # 69
Replastering of walls after DPC installation must account for:

  • A. No special considerations
  • B. Only appearance
  • C. Salt content reduction through drying/removal, use of compatible low-salt plaster, and appropriate finishes
  • D. Only speed of application

正解:C


質問 # 70
A surveyor reports on penetrating damp in a cavity wall property. The report should include:

  • A. Only moisture meter readings
  • B. Only aesthetic observations
  • C. Location of damp internally, corresponding external defects photographed, assessment of cavity integrity, insulation condition, and recommended repair prioritization
  • D. Only recommendations without investigation details

正解:C


質問 # 71
A commercial property has severe rising damp but alternative treatments (electro-osmotic, capillary breaks) cannot be installed due to structural constraints. The surveyor's recommendation should include:

  • A. Demolition of the building
  • B. Only internal cosmetic treatments
  • C. Accepting permanent damp
  • D. Conventional chemical DPC installation as appropriate method, with realistic expectations regarding moisture reduction timescale

正解:D


質問 # 72
Professional reporting of a complex damp problem (multiple sources) should:

  • A. Clearly identify all sources, provide evidence for each diagnosis, explain interactions, and recommend prioritized solutions
  • B. Simplify to only one diagnosis
  • C. Avoid technical detail
  • D. Provide only recommendations without evidence

正解:A


質問 # 73
The survey report must communicate findings clearly to:

  • A. No one; findings are confidential
  • B. Building owners, occupants, and professionals who may not be surveyors
  • C. Only building professionals
  • D. Only moisture specialists

正解:B


質問 # 74
An electrical resistance moisture meter reading in masonry affected by rising damp will be:

  • A. Unaffected by salts
  • B. Always accurate
  • C. Always accurate regardless of salt content
  • D. Artificially lowered due to high salt content increasing conductivity

正解:D


質問 # 75
To diagnose condensation as opposed to rising or penetrating damp, the surveyor should observe:

  • A. Moisture at all heights
  • B. Surface condensation without salt deposits, appearing in cold corners and on windows
  • C. Damp only after rainfall
  • D. Tide marks at ground level

正解:B


質問 # 76
When a surveyor concludes that a property's damp problem is primarily caused by condensation resulting from occupant behavior (drying washing indoors, inadequate ventilation), the recommendation should:

  • A. Ignore occupant factors
  • B. Explain the technical cause, recommend occupant action changes, and suggest building improvements to reduce condensation risk
  • C. Only blame occupants
  • D. Recommend expensive structural works

正解:B


質問 # 77
Following chemical DPC installation at 150mm spacing using BS 6576 procedures, the surveyor must verify:

  • A. Work commenced immediately after injection
  • B. Chemical has circulated through wall and cure time allows for replastering; high-salt contamination addressed through drying/salt removal
  • C. No replastering needed
  • D. Moisture will decrease within days

正解:B


質問 # 78
Condensation typically appears as:

  • A. Damp patches linked to external defects
  • B. Tide marks with salt deposits
  • C. Black mould on walls, ceilings, windows, and cold surfaces
  • D. Brown staining on brickwork

正解:C


質問 # 79
A property shows damp with characteristic black mould appearing in winter only, no salt deposits, high relative humidity (70%+), and visible condensation on windows. The cause is most likely:

  • A. Condensation from occupancy, inadequate ventilation, and poor heating
  • B. Penetrating damp
  • C. Structural failure
  • D. Rising damp

正解:A


質問 # 80
The scope and limitations of the survey should be stated in the report because:

  • A. It is not important
  • B. It is optional
  • C. Surveyors do not need to disclose limitations
  • D. It clarifies what was and was not investigated, allowing clients to understand the basis of conclusions

正解:D


質問 # 81
BS 5250:2021 addresses condensation control through:

  • A. Preventing occupancy
  • B. Eliminating all moisture
  • C. Adequate ventilation, thermal insulation, and moisture management to control relative humidity
  • D. Using dehumidifiers only

正解:C


質問 # 82
A basement property shows seepage through walls below water table level. The surveyor must specify waterproofing per BS 8102:2022. Type A protection involves:

  • A. Accepting water ingress
  • B. Only internal treatment
  • C. External drained cavity system allowing water to enter but collecting and draining it safely
  • D. Sealed barrier membrane

正解:C


質問 # 83
......

CSDB問題集完全版解答試験学習ガイド:https://jp.fast2test.com/CSDB-premium-file.html

リアルCSDBは100%カバー率でリアル試験解答を試そう:https://drive.google.com/open?id=1_rNaZifULqQhYW6gLFHE7oLH7Bl-g0rV


弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

我々の働いている時間: ( GMT 0:00-15:00 )
月曜日から土曜日まで

サポート: 現在連絡 

English Deutsch 繁体中文 한국어